Skip to main content
. 2021 Oct 28;217(8):80. doi: 10.1007/s11214-021-00855-2

Fig. 2.

Fig. 2

Time histories of the MagEIS bias voltages. The raw instrument housekeeping data have been interpolated to a 5-minute time cadence using a nearest neighbor approach. New flight software uploads are indicated with magenta ellipses and instances where the bias was disabled are shown with red ellipses. The M35-A unit had considerable noise in its housekeeping measurements (see Sect. 6.15)