Parameters Used in Electron Sensor Response and Bowtie Analysis

B-field scalinga [%] Temp. [C] Power law indices Exponential energies [MeV]
LOW-A 102 to 106.5 −10 −0.5,−1,−1.5,−2,−2.5,−3,−3.5,−4 0.02,0.04,0.06,0.08,0.1
LOW-B 102 to 106.5 −10 “ ” “ ”
M35-A 100 to 100 −11 0,−0.5,−1,−1.5,−2,−2.5,−3,−3.5,−4 0.1,0.2,0.3,0.4,0.5,0.6,0.7,0.8,0.9,1.0
M35-B 101 to 103 −9 “ ” “ ”
M75-A 101 to 102 −10 “ ” “ ”
M75-B 101 to 103 −7.5 “ ” “ ”
HIGH-A 94 to 111.5 −5 −5,−6,−7,−8 0.25,0.34,0.43,0.51,0.60
HIGH-B 94 to 110 −5 “ ” “ ”

aFor each unit, a different scaling is used for each pixel in the “hybrid” response function (see Electronic Supplementary Material). The values shown here indicate the range of scalings used