Skip to main content
. 2021 Oct 15;12:706610. doi: 10.3389/fneur.2021.706610

Table 2.

NeuroFlexor components and amplitude of electromyography signal before, during, and after stimulation with EXOPULSE Mollii.

Variables OFF-settings 20 Hz 30 Hz
Before During After Before During After Before During After
Upper extremity NC 11.24 (11.96) 12.30 (10.80) 13.87 (7.20) 12.28 (11.68) 12.71 (10.17) 13.44 (10.78) 13.35 (8.88) 12.97 (9.05) 14.76 (12.52)
EC 3.85 (2.80) 4.60 (3.01) 4.15 (3.25) 4.07 (3.76) 4.80 (4.63) 4.22 (2.54) 4.08 (3.33) 4.57 (3.67) 3.56 (2.40)
Total resistance 18.27 (12.74) 17.24 (13.75) 18.44 (7.61) 16.70 (12.72) 18.50 (11.68) 18.98 (9.83) 17.17 (11.57) 19.41 (10.40) 19.31 (13.63)
FCR EMG 0.072 (0.04) 0.069 (0.05) 0.061 (0.06) 0.075 (0.09) 0.061 (0.04) 0.060 (0.05)
Lower extremity NC 33.64 (34.22) 31.54 (27.19) 34.02 (33.45) 38.85 (29.54) 35.16 (34.29) 31.41 (38.04) 35.31 (34.57) 33.66 (36.00) 37.54 (31.65)
EC 59.63 (25.95) 58.04 (32.85) 63.67 (33.51) 53.14 (30.14) 60.73 (16.65) 60.14 (29.11) 59.04 (17.91) 60.93 (14.86) 60.69 (22.74)
Total resistance 104.42 (29.75) 100.16 (37.96) 113.47 (28.00) 102.86 (26.88) 109.06 (24.79) 104.49 (26.89) 104.66 (27.22) 111.52 (32.02) 106.79 (28.05)
Gastrocnemius EMG 0.053 (0.03) 0.059 (0.03) 0.048 (0.02) 0.053 (0.05) 0.052 (0.02) 0.048 (0.04)
Soleus EMG 0.067 (0.05) 0.057 (0.07) 0.053 (0.05) 0.055 (0.04) 0.045 (0.03) 0.052 (0.03)

Values in median (IQR).

NeuroFlexor neural component (NC), elastic component (EC), and total resistance (in Newton, N), and amplitude of electromyography (EMG) signal (in mV) in the upper extremity (N = 20) and lower extremity (n = 10). FCR, flexor carpi radialis muscle.