Cryo-EM data collection, refinement, and validation statistics.

tcTRP248SS (EMD-24425) (PDB 7RDR)
Data collection and processing
 Magnification 38 Kx
 Voltage (kV) 200
 Electron exposure (e–/Å2) 40
 Defocus range (μm) −0.8 to −2.3
 Pixel size (Å) 1.16
 Symmetry imposed C3
 Initial particle images (no.) 627763
 Final particle images (no.) 121426
 Map resolution (Å) 6.9
  FSC threshold 0.143
 Map resolution range (Å) 30–6.9
Refinement
 Initial model used (PDB code) tcTRP248SS
 Model resolution (Å) 6.9
  FSC threshold 0.143
 Model resolution range (Å) 30–6.9
 Map sharpening B factor (Å2) −418.6
 Model composition
  Non-hydrogen atoms None
  Protein residues 1368
  Ligands None
 B factors (Å2)
  Protein 20.0
  Ligand N/A
 R.m.s. deviations
  Bond lengths (Å) 0.01
  Bond angles (°) 1.2
 Validation
  MolProbity score 1.6
  Clashscore 1.05
  Poor rotamers (%) 0
 Ramachandran plot
  Favored (%) 98.32
  Allowed (%) 1.68
  Disallowed (%) 0