Table 2.
Cryo-EM data collection, refinement, and validation statistics.
tcTRP248SS (EMD-24425) (PDB 7RDR) | |
---|---|
Data collection and processing | |
Magnification | 38 Kx |
Voltage (kV) | 200 |
Electron exposure (e–/Å2) | 40 |
Defocus range (μm) | −0.8 to −2.3 |
Pixel size (Å) | 1.16 |
Symmetry imposed | C3 |
Initial particle images (no.) | 627763 |
Final particle images (no.) | 121426 |
Map resolution (Å) | 6.9 |
FSC threshold | 0.143 |
Map resolution range (Å) | 30–6.9 |
Refinement | |
Initial model used (PDB code) | tcTRP248SS |
Model resolution (Å) | 6.9 |
FSC threshold | 0.143 |
Model resolution range (Å) | 30–6.9 |
Map sharpening B factor (Å2) | −418.6 |
Model composition | |
Non-hydrogen atoms | None |
Protein residues | 1368 |
Ligands | None |
B factors (Å2) | |
Protein | 20.0 |
Ligand | N/A |
R.m.s. deviations | |
Bond lengths (Å) | 0.01 |
Bond angles (°) | 1.2 |
Validation | |
MolProbity score | 1.6 |
Clashscore | 1.05 |
Poor rotamers (%) | 0 |
Ramachandran plot | |
Favored (%) | 98.32 |
Allowed (%) | 1.68 |
Disallowed (%) | 0 |