Skip to main content
. 2021 Oct 29;4:1238. doi: 10.1038/s42003-021-02767-x

Table 2.

Cryo-EM data collection, refinement, and validation statistics.

(EMDB/PDB ID) TlCPC-6 (EMD-31090/7EH8) TlCPC-8 (EMD-31089/7EH7)
Data collection and processing
  Microscope Talos Arctica Talos Arctica
  Voltage (kV) 200 200
  Detector Falcon 3EC Falcon 3EC
  Magnification 120,000 120,000
  Pixel size (Å) 0.88 0.88
  Automation software EPU EPU
  Total exposure (e2) 50 50
  Exposure rate (e2 fraction) 1.02 1.02
  Number of frames 49 49
  Defocus range (μm) −1, −1.5, −2, −2.5 −1, −1.5, −2, −2.5
  Number of collected micrograph 2,036 2,036
  Number of particles for Class2D 283,980 129,653
  Number of particles for Class3D 72,655 23,643
  Number of particles for Refine3D 28,120 10,402
  Symmetry imposed D3 D4
  Map resolution (Å) 3.06 3.71
   FSC threshold 0.143 0.143
  Map resolution range (Å) 2.91–3.38 3.47–4.49
Refinement
  Refinement programs PHENIX/Coot PHENIX/Coot
  Initial model used (PDB code) 7EFW 7EFV
  Map-to-model resolution (Å) 3.05 3.75
   FSC threshold 0.5 0.5
  Model resolution range (Å) 2.91–3.38 3.47–4.49
  Model composition
   Non-hydrogen atoms 15773 20904
   Protein residues 2004 2656
   Ligands 18 24
  B factors (Å2)
   Protein 38.8 51.9
   Ligand 39.4 51.2
  Map-model CC
   CC (mask) 0.90 0.86
   CC (box) 0.77 0.80
   CC (peaks) 0.75 0.75
   CC (volume) 0.85 0.83
  R.m.s. deviations
   Bond lengths (Å) 0.003 0.004
   Bond angles (°) 1.051 1.298
  Validation
   MolProbity score 1.3 1.7
   Clash score 5.5 8.7
   Poor rotamer (%) 0.79 1.69
  Ramachandran plot
   Favored (%) 98.2 97.8
   Allowed (%) 1.8 2.2
   Disallowed (%) 0 0