TABLE 1.
The means (standard deviations) of the RMSE (unit: mm) for the femur and tibia shape reconstruction using 1, 2, and 3 image pairs by computer simulation. p values of a univariate analysis with a polynomial linear test are also given for the trend of reconstruction accuracy with increasing image pairs.
| 1 image pair | 2 image pairs | 3 image pairs | |||
|---|---|---|---|---|---|
| Computer simulation | Femur | 0.62 (0.075) | 0.57 (0.088) | 0.52 (0.09) | 0.048* |
| Tibia | 0.72 (0.076) | 0.67 (0.074) | 0.63 (0.085) | 0.049* | |
*: p< 0.05, significant linear trend.