Table 2.
Technical aspects of 68Ga-PSMA-11 PET/CT and mpMRI scans.
| Author | Year | mpMRI | 68Ga-PSMA-PET/CT | |||
|---|---|---|---|---|---|---|
| Field strength | MRI sequence | Injection dose | Uptake time (min) | Image analysis | ||
| Frumer et al. (28) | 2020 | 3.0 or 1.5 T | T2WI, DWI, DCE | 3–5 mCi | 50–60 | Visual |
| Franklin et al. (32) | 2020 | 3.0 T | T2WI, DWI, DCE | Mean, 200 MBq | 45–60 | Visual |
| Kulkarni et al. (26) | 2020 | 3.0 T | T2WI, DWI, DCE | 3–4.5 mCi | 60 | Visual |
| Pallavi et al. (31) | 2020 | 3.0 T | T2WI, DWI | Mean, 1.76 MBq/kg | 60 | Visual |
| Van Leeuwen et al. (24) | 2019 | 3.0 or 1.5 T | T2WI, DWI, DCE | 2.0 MBq/kg or 100 MBq | 60 or 45 | NA |
| Yilmaz et al. (23) | 2019 | 3.0 T | T2WI, DWI, DCE | Median, 175 MBq | 60 | Quantitative |
| Berger et al. (21) | 2018 | 3.0 T | T2WI, DWI | NA | 60 | Quantitative |
| Gupta et al. (20) | 2017 | 1.5 T | T2WI, DWI | 2 MBq/kg | 60 | Visual |
| Zhang et al. (19) | 2017 | 3.0 T | T2WI, DWI, DCE | Median 131.7 MBq | 60 | Visual |