Skip to main content
. 2021 Oct 20;11:737989. doi: 10.3389/fonc.2021.737989

Table 2.

Technical aspects of 68Ga-PSMA-11 PET/CT and mpMRI scans.

Author Year mpMRI 68Ga-PSMA-PET/CT
Field strength MRI sequence Injection dose Uptake time (min) Image analysis
Frumer et al. (28) 2020 3.0 or 1.5 T T2WI, DWI, DCE 3–5 mCi 50–60 Visual
Franklin et al. (32) 2020 3.0 T T2WI, DWI, DCE Mean, 200 MBq 45–60 Visual
Kulkarni et al. (26) 2020 3.0 T T2WI, DWI, DCE 3–4.5 mCi 60 Visual
Pallavi et al. (31) 2020 3.0 T T2WI, DWI Mean, 1.76 MBq/kg 60 Visual
Van Leeuwen et al. (24) 2019 3.0 or 1.5 T T2WI, DWI, DCE 2.0 MBq/kg or 100 MBq 60 or 45 NA
Yilmaz et al. (23) 2019 3.0 T T2WI, DWI, DCE Median, 175 MBq 60 Quantitative
Berger et al. (21) 2018 3.0 T T2WI, DWI NA 60 Quantitative
Gupta et al. (20) 2017 1.5 T T2WI, DWI 2 MBq/kg 60 Visual
Zhang et al. (19) 2017 3.0 T T2WI, DWI, DCE Median 131.7 MBq 60 Visual