Table 1.
Code name | Source | Delta stability (kcal/mol) | Delta net charge | Positive patch size change (Ang2) | Negative patch size change (Ang2) | Positive CDR patch size change (Ang2) | Negative CDR patch size change (Ang2) | Fv charge (at pH 5.5) |
Purification result |
---|---|---|---|---|---|---|---|---|---|
−14 | MOE | 5.38 | −13.6 | −10 | 480 | 0 | 480 | −7.9 | Successful |
−12 | MOE | 5.25 | −12.4 | −40 | 380 | 0 | 380 | −8.9 | Successful |
−11 | MOE | 4.95 | −11.4 | −10 | 460 | −10 | 460 | −6.1 | Successful |
−8 | Manual | 1.72 | −8.4 | 0 | 270 | −10 | 270 | −2.4 | Successful |
−4 | Ref.12 | 1.15 | −3.4 | 50 | 150 | 0 | 150 | +2.3 | Successful |
+5 | Ref.12 | 2.27 | +4.6 | 140 | −40 | 140 | −40 | +10.9 | Successful |
+11 | Manual | −0.17 | +10.8 | 430 | −40 | 430 | −40 | +16.8 | Aggregation |
+15 | MOE | 1.50 | +15.87 | 750 | −30 | 710 | −30 | +20.9 | Failed |
+16 | MOE | 1.58 | +15.98 | 630 | −40 | 640 | −40 | +21.1 | Aggregation |
+17 | MOE | 0.82 | +16.79 | 720 | −60 | 800 | −60 | +22.0 | Aggregation |