Skip to main content
. 2021 Mar 4;60(11):5271–5281. doi: 10.1093/rheumatology/keab210

Table 3.

Sensitivity, specificity, and positive and negative predictive values of ACR/EULAR-2019 and SLICC-2012 criteria

Classification criteria Sensitivity
Specificity
Positive predictive value
Negative predictive value
First
visit (%)
Last
visit (%)
First
visit (%)
Last
visit (%)
First visit (%) Last
visit (%)
First
visit (%)
Last
visit (%)
ACR/EULAR-2019 94 96 77 81 88 93 87 89
SLICC-2012 98 98 67 71 84 89 94 94

P-values

<0.001

*

<0.001

*

<0.001

*

<0.001

*

<0.001

**

<0.001

**

<0.001

**

<0.001

**

The ACR-1997 criteria were used as reference criteria for calculation of sensitivities, specificities, and positive and negative predictive values. *P-values were calculated using the χ2d test, comparing the sensitivities or specificities obtained by the different classification criteria (ACR/EULAR-2019 vs SLICC-2012) at each time point. **P-values calculated using a binomial exact test, and relating to positive predictive value and negative predictive value for each set of criteria.