Skip to main content
. 2021 Nov 3;11:21615. doi: 10.1038/s41598-021-00812-7

Table 4.

Accuracy (mean and standard deviation) without considering a priori knowledge i.e. Asymmetry - Within-subject. The best performance value is highlighted in bold.

Classifier Entire EEG band Filter bank
No PCA/CSP PCA CSP No PCA/CSP PCA CSP
k-NN 71.0 ± 6.0 67.7 ± 8.4 72.0 ± 8.9 75.6 ± 5.8 66.8 ± 7.2 94.5 ± 3.5
SVM 66.9 ± 8.1 66.3 ± 10.3 73.4 ± 9.5 71.6 ± 8.9 62.0 ± 7.8 95.5 ± 2.8
LDA 63.1 ± 4.9 55.3 ± 4.0 74.0 ± 10.0 62.9 ± 5.3 53.9 ± 3.5 95.0 ± 2.9
ANN 69.7 ± 5.1 66.3 ± 6.2 78.1 ± 8.0 66.7 ± 4.9 65.6 ± 5.6 96.1 ± 3.0
RF 66.4±4.1 58.9±4.2 72.8±9.4 67.4±4.1 59.3±5.0 94.2±2.7
LR 62.7±4.9 52.3±2.9 72.6±9.3 61.0±5.0 51.2±4.0 95.1±2.9