Skip to main content
. 2021 Oct 28;2021:5208940. doi: 10.1155/2021/5208940

Table 7.

Comparison table of detection indexes for patchy lungs with field consolidation.

The Canny algorithm The HMS algorithm The ETAR algorithm The proposed algorithm
MSE 1.3192 5.617 1.3313 1.1690
SNR 0.0397 3.2443 2.8746 10.4839
MAE 195.9766 174.4995 196.9860 41.1912