Data of Wt. loss method for corrosion of carbon steel in 1 M HCl solution with and without various concentrations of PdC-OH, PdC-Me and PdC-H compounds at 25 °C ± 0.1.

Compounds Conc. M C.R (mg/cm2/min) θ %η
1 M HCl Blank 0.029 ± 0.0023
PdC-OH 2 × 10–5 0.012 ± 0.0015 0.586 58.6
4 × 10–5 0.011 ± 0.0012 0.604 60.4
6 × 10–5 0.011 ± 0.0018 0.619 61.9
8 × 10–5 0.010 ± 0.0009 0.662 66.2
1 × 10–4 0.007 ± 0.0029 0.757 75.7
PdC-Me 2 × 10–5 0.017 ± 0.0020 0.425 42.5
4 × 10–5 0.014 ± 0.0009 0.526 52.6
6 × 10–5 0.012 ± 0.0023 0.575 57.5
8 × 10–5 0.011 ± 0.0017 0.615 61.5
1 × 10–4 0.008 ± 0.0020 0.727 72.7
PdC-H 2 × 10–5 0.018 ± 0.0017 0.397 40.0
4 × 10–5 0.014 ± 0.0015 0.515 51.5
6 × 10–5 0.014 ± 0.0026 0.525 52.5
8 × 10–5 0.012 ± 0.0026 0.598 59.8
1 × 10–4 0.009 ± 0.0023 0.704 70.4