Skip to main content
. 2021 Oct 22;28(Pt 6):1769–1777. doi: 10.1107/S1600577521010493

Table 2. Settings of sCT scans of hoof #9 acquired at the Australian Synchrotron IMBL to determine optimal energy and distance from the detector for subsequent scans.

The area of interest was the equine lamina, which connects the hoof bone to the hoof capsule.

Scan # Energy (keV) Pixel size (µm) Detector distance (m)
1 80 12 6
2 60 12 6
3 70 12 6
4 80 12 6
5 55 12 6
6 55 12 3