Skip to main content
. 2021 Oct 21;297(5):101322. doi: 10.1016/j.jbc.2021.101322

Table 1.

Data collection and refinement statistics for the XC-43-thrombin complex

Crystal Thrombin/XC-43
Resolution (Å) 50–2.15
Beamline 22-ID
Wavelength (Å) 1.000
Completeness (total/high resolution shell) 99.9/100
Average Redundancy (total/high resolution shell) 11.2/11.6
Rmerge (total/high resolution shell, %) 8.5/69.7
CC1/2 (total/high resolution shell) 99.9/94.2
I/sigI (total/high resolution shell) 18.3/4.2
Observed reflections 1,825,903
Unique Reflections 163,186
Space group P212121
Unit cell dimensions (Å)
 a 113.3
 b 136.3
 c 193.9
 α, β, γ (˚) 90
Refinement
 Total non-H protein atoms 15,074
 Total non-H solvent atoms 1163
 RMS deviations
 Bond lengths (Å) 0.007
 Bond angles (˚) 0.868
 Mean B factors (Å2)
 Protein 42.97
 Solvent 45.43
 Molprobity analysis
 Ramachandran plot (favored/allowed, %) 97.42/2.58
 Clashscore 1.68
 Rotamer outliers (%) 0.5
Coordinate error ML (Å, Phenix) 0.18
Rcryst/Rfree 0.166/0.193