Figure 3:
Experimental workflow for excised canine OS tumor histotripsy treatment and analysis. OS samples were harvested after standard-of-care limb amputation, fixed in gelatin for treatment, treated with a 500-kHz histotripsy transducer using 1–2 cycle pulses at a dosage of 4,000 pulses per point, and histologically analyzed after treatment.