Quantitative data for tau + shRNA axonal transport experiments

Experimental conditions Anterograde segment velocity (µm/s) Retrograde segment velocity (µm/s) Total pause frequency (pauses/s) Anterograde pause frequency (pauses/s) Retrograde pause frequency (pauses/s)
Control shRNA
    WT tau 1.81 ± 0.33 1.93 ± 0.22 0.155 ± 0.038 0.072 ± 0.028 0.121 ± 0.025
    P301L tau 2.00 ± 0.37 2.24 ± 0.27 0.356 ± 0.109 0.184 ± 0.055 0.206 ± 0.085
    R5L tau 2.10 ± 0.34 2.32 ± 0.34 0.336 ± 0.112 0.206 ± 0.057 0.226 ± 0.086
PP1α shRNA
    WT tau 2.22 ± 0.36 2.26 ± 0.11 0.222 ± 0.039 0.158 ± 0.049 0.169 ± 0.025
    P301L tau 2.30 ± 0.56 2.36 ± 0.27 0.339 ± 0.051 0.230 ± 0.063 0.237 ± 0.022
    R5L tau 2.30 ± 0.20 2.24 ± 0.25 0.324 ± 0.059 0.253 ± 0.082 0.175 ± 0.040
PP1γ shRNA
    WT tau 1.85 ± 0.43 2.01 ± 0.29 0.168 ± 0.032 0.089 ± 0.019 0.126 ± 0.035
    P301L tau 1.96 ± 0.30 2.08 ± 0.30 0.156 ± 0.020 0.087 ± 0.010 0.106 ± 0.015
    R5L tau 2.00 ± 0.15 2.06 ± 0.21 0.227 ± 0.035 0.139 ± 0.046 0.155 ± 0.043

This table includes mean values ± SD for axonal transport directional segment velocities and total and directional pause frequencies from the tau expression groups within each shRNA treatment group (Fig. 7E–I).