Table 5. Streams and Cost Data for Case 3a.
stream | Tin/°C | Tout/°C | FCp/kW·°C–1 | h/kW·m–2·°C–1 |
---|---|---|---|---|
H1 | 385 | 159 | 131.51 | 1.238 |
H2 | 516 | 43 | 1198.96 | 0.546 |
H3 | 132 | 82 | 378.52 | 0.771 |
H4 | 91 | 60 | 589.545 | 0.859 |
H5 | 217 | 43 | 186.216 | 1 |
H6 | 649 | 43 | 116 | 1 |
C1 | 30 | 385 | 119.1 | 1.85 |
C2 | 99 | 471 | 191.05 | 1.129 |
C3 | 437 | 521 | 377.91 | 0.815 |
C4 | 78 | 418.6 | 160.43 | 1 |
C5 | 217 | 234 | 1297.7 | 0.443 |
C6 | 256 | 266 | 2753 | 2.085 |
C7 | 49 | 149 | 197.39 | 1 |
C8 | 59 | 163.4 | 123.156 | 1.063 |
C9 | 163 | 649 | 95.98 | 1.81 |
C10 | 219 | 221.3 | 1997.5 | 1.377 |
HU1 | 1800 | 800 | 1.2 | |
HU2 | 509 | 509 | 1.0 | |
CU | 38 | 82 | 1.0 |
Area cost = 26,600 + 4147.5A0.6 $·year–1, A in m2. HU1 cost = 35 $·kW–1·year–1, HU2 cost = 27 $·kW–1·year–1, and CU cost = 2.1 $·kW–1·year–1.