Skip to main content
. 2021 Nov;42(11):1993–2000. doi: 10.3174/ajnr.A7311

Table 3:

Pressure values before and after venous sinus stent placementa

Before
After
Data Available (%) (No.) Data Available (%) (No.)
CSF opening pressure (cm H2O) 84.6% (11/13) 31 (23–38) CSF opening pressure (cm H2O) 76.9% (10/13) 21 (18.75–29.25)
CSF opening pressure improvement (mm Hg) 76.9% (10/13) −9.25 (−20.7 to −5.7)
Transstenotic pressure gradient in GA (mm Hg) 100% (13/13) 9 (5–15) Transstenotic pressure gradient in GA (mm Hg) 100% (13/13) 1 (0–2)
Transstenotic pressure gradient improvement (in mm Hg) 100% (13/13) −8 (−15 to −3.5)
Transstenotic pressure gradient on diagnosis in LA (mm Hg) 92.3% (12/13) 22.5 (13.25– 26.25) Transstenotic pressure gradient at 6-mo follow-up in LA (mm Hg) 92.3% (12/13) 1.5 (0.25– 5)
Transstenotic pressure gradient improvement at 6-mo follow-up (mm Hg) 92.3% (12/13) −19 (−21.75 to −13.25)

Note:—LA indicates local anesthesia; GA, general anesthesia.

a

Data are expressed as percentages (No.) or median (interquartile range [25%–75%]).