Skip to main content
. 2021 Oct 25;14(21):6381. doi: 10.3390/ma14216381

Table 1.

Average values and standard deviations of the results for the tensile tests on specimens manufactured by Compression Molding (CM) and Injection Molding (IM):( X¯ indicates the average value, STD the standard deviation).

Et [MPa] σy [MPa] Ɛy % σb [MPa] Ɛb %
X¯ STD X¯ STD X¯ STD X¯ STD X¯ STD
CM 691.10 24.89 35.83 2.17 5.59 0.003 32.27 1.89 503.70 37.59
IM 881.50 10.11 46.34 1.39 6.75 0.25 31.14 2.53 145.45 109.54