Table 1.
Average values and standard deviations of the results for the tensile tests on specimens manufactured by Compression Molding (CM) and Injection Molding (IM):( indicates the average value, STD the standard deviation).
Et [MPa] | σy [MPa] | Ɛy % | σb [MPa] | Ɛb % | ||||||
---|---|---|---|---|---|---|---|---|---|---|
STD | STD | STD | STD | STD | ||||||
CM | 691.10 | 24.89 | 35.83 | 2.17 | 5.59 | 0.003 | 32.27 | 1.89 | 503.70 | 37.59 |
IM | 881.50 | 10.11 | 46.34 | 1.39 | 6.75 | 0.25 | 31.14 | 2.53 | 145.45 | 109.54 |