Skip to main content
. 2021 Oct 28;14(21):6487. doi: 10.3390/ma14216487

Table 4.

The MAC of bulk samples using experimental and theoretical methods and the relative deviation between the experimental and XCOM (1%) as well as the relative deviation between the experimental and Geant4 simulation (2%).

Sample Energy, MeV MAC, cm2/g 1% 2%
XCOM EXP Geant4
C-0 0.0595 0.3708 0.3754 0.3736 1.23 0.46
0.662 0.1670 0.1696 0.1710 1.55 −0.85
0.122 0.1182 0.1194 0.1182 1.01 1.01
0.245 0.1026 0.1016 0.1018 −0.98 −0.22
0.344 0.0774 0.0765 0.0760 −1.2 0.65
0.964 0.0649 0.0657 0.0654 1.22 0.45
1.408 0.0588 0.0585 0.0586 −0.55 −0.25
1.173 0.0551 0.0555 0.0550 0.78 0.99
1.333 0.0536 0.0541 0.0538 0.88 0.42
C-B5 0.0595 0.4440 0.4484 0.4508 −0.97 −0.55
0.662 0.2126 0.2100 0.2113 1.24 −0.63
0.122 0.1254 0.1246 0.1235 0.63 0.87
0.245 0.1055 0.1068 0.1058 −1.25 0.99
0.344 0.0779 0.0795 0.0799 −1.97 −0.58
0.964 0.0650 0.0660 0.0665 −1.53 −0.77
1.408 0.0589 0.0588 0.0582 0.19 1.02
1.173 0.0552 0.0545 0.0542 1.15 0.54
1.333 0.0536 0.0539 0.0539 −0.58 0.12
C-B7 0.0595 0.4698 0.4772 0.4762 1.58 0.22
0.662 0.2325 0.2305 0.2285 −0.87 0.85
0.122 0.1285 0.1301 0.1295 1.22 0.44
0.245 0.1068 0.1049 0.1038 −1.82 1.02
0.344 0.0781 0.0793 0.0797 1.44 −0.58
0.964 0.0651 0.0656 0.0649 0.77 1.01
1.408 0.0589 0.0591 0.0598 0.28 −1.15
1.173 0.0552 0.0557 0.0559 1.024 −0.25
1.333 0.0536 0.0544 0.0541 1.44 0.55