Table 1.
Initial material test results.
No. | Load Diagram | Test | Material | Result |
---|---|---|---|---|
A |
![]() |
Compressive strength (EN 772-1 [46]) |
Brick | fb = 44.1 MPa |
B |
![]() |
Young and Poisson | Brick |
E = 11,850 MPa ν = 0.11 |
C |
![]() |
Flexural strength | Brick | f = 3.2 MPa |
D |
![]() |
Flexural strength (EN 1015-11 [47]) |
Mortar | f = 3.3 MPa |
E |
![]() |
Compressive strength (EN 1015-11 [47]) |
Mortar | fm = 10.9 MPa |
F |
![]() |
Young and Poisson | Mortar |
E = 10,580 MPa ν = 0.17 |
G |
![]() |
Shear strength (EN 1052-3 [48]) |
Masonry |
fvo = 0.50 MPa tg(α) = 0.5 |