Table 1. Fitted Exponents
γ of the Fit
of the Power Law
to the Pressure Dependence of the Hydrogen
Absorption Rate Ra.
| No PTFE |
PTFE |
|||||||
|---|---|---|---|---|---|---|---|---|
| 28 °C | 60 °C | 90 °C | 120 °C | 28 °C | 60 °C | 90 °C | 120 °C | |
| Pd | 0.71 | 0.89 | 1.00 | 1.02 | 0.74 | 0.98 | 1.05 | 1.17 |
| Pd0.7Au0.3 | 0.84 | 0.86 | 0.99 | 1.09 | 0.73 | 0.93 | 1.04 | 1.14 |
| Pd0.6Au0.4 | 0.91 | 0.90 | 1.07 | 1.12 | 0.73 | 0.90 | 1.04 | 1.14 |
| Pd0.5Au0.5 | 0.87 | 0.87 | 1.02 | 1.10 | 0.63 | 0.79 | 0.98 | 1.12 |
| Ni | 0.67 | 0.63 | 0.78 | 0.88 | 0.66 | 0.65 | 0.87 | 0.97 |
| Pt | 0.75 | 0.53 | 0.63 | 0.64 | 0.70 | 0.51 | 0.63 | 0.65 |
| Ru | 0.64 | 0.64 | ||||||