Skip to main content
. 2021 Oct 23;21(21):7027. doi: 10.3390/s21217027

Table 5.

Effective thermal conductivity of the ground below 60 m depth for each borehole in each month of the measurement obtained with Equation (2). The mean and the standard deviation of the values in each borehole are included. (* Less than 10 m of log was used, ** Damaged grouting).

Borehole λ ( W m1 K1) Average
Relative Error (%)
Oct. Nov. Dec. Jan. Feb. Mar.
B0 - - 2.48 2.50 2.28 2.45 8.9
* B2 4.20 2.52 5.59 2.88 3.03 3.67 70.8
C1 - 2.36 2.37 2.40 2.25 2.27 8.9
D 2.62 2.75 2.53 2.54 2.34 2.61 4.9
E2 2.96 2.69 2.53 2.37 2.28 2.24 4.8
E3 2.58 2.83 2.42 2.43 2.48 2.41 2.6
** F1 4.14 5.08 3.90 - - 3.98 16.1
G0 2.78 2.66 2.56 2.48 2.57 2.57 1.9