Table 2.

Comparison of signal filtering methods in the saturation mode of current transformers when determining the angle and the effective value of signals according to M2.

Method and
Reference
Computational
Experiment 1
Computational
Experiment 22
Computational
Experiment 3
Computational
Experiment 4
fi, % Δφ, ° fi, % Δφ, ° fi, % Δφ, ° fi, % Δφ, °
Max Avg. Max Avg. Max Avg. Max Avg. Max Avg. Max Avg. Max Avg. Max Avg.
A1 [11,12] 3.7 2.5 0.7 0.2 45 43 12 6.6 4.3 1.7 3 1.7 43 42 14 8
A2 [15,16,17] 1 0.4 0.7 0.3 0.7 0.3 0.4 0.16 27 15 19 11 48 26 27 15
A3 [18] 37 26 30 24 37 25 30 24 84 78 109 93 84 78 110 93
A4 [19,20,21,22,23,24,25] 2 0.4 3.5 2 1 0.2 1 0.7 2 1 1.6 1.3 2 0.8 1.5 1.2