Optimal ACT slope angles for different methods.

Wave Mode Optimal ACT Slope Angle [deg]
Numerical Results PZT Measurements ACT Measurements
direction along fibres
A0 16.9 17 ± 0.5 16 ± 1
S0 2.1 2.1 ± 0.05 -
SH0 11.2 - -
direction across fibres
A0 31.7 31.6 ± 1 34 ± 1
S0 8 7.2 ± 0.2 -
SH0 11.2 - 10 ± 1