Skip to main content
. 2020 Nov 14;33(7):462–466. doi: 10.1016/j.sdentj.2020.11.004

Table 4.

Paired Sample T-Test comparing each material to a natural tooth.

Paired differences
T DF Sig. (2-Tailed)
Mean Std. Deviation Std. Error Mean 95% Confidence Interval of the Difference
Lower Upper
Pair 1 Ceramic - NaturalTooth −3.46250 3.81796 1.90898 −9.53773 2.61273 −1.814 3 0.167
Pair 2 Zircon - NaturalTooth −2.99750 4.32699 2.16349 −9.88270 3.88770 −1.385 3 0.260
Pair 3 Composite - NaturalTooth 6.94250 4.86560 2.43280 −0.79976 14.68476 2.854 3 0.065
Pair 4 F.composite - NaturalTooth 0.83750 2.64146 1.32073 −3.36565 5.04065 0.634 3 0.571
Pair 5 GIC - NaturalTooth −1.41000 3.55965 1.77983 −7.07420 4.25420 −0.792 3 0.486