Skip to main content
. 2021 Nov 15;15(6):922–929. doi: 10.5009/gnl20257

Table 3.

Detailed Information on Endoscopic Biliary Drainage Revisions

Variable BMS group (n=35) MPS group (n=67) p-value
Re-intervention rate 14 (40.0) 38 (56.7) 0.11
No. of revision (n=52) 0.45
1 10 (71.4) 13 (34.2)
2 1 (7.1) 10 (26.3)
3 1 (7.1) 5 (13.2)
4 1 (7.1) 5 (13.2)
5 1 (7.1) 1 (2.6)
6 0 1 (2.6)
7 0 2 (5.3)
10 0 1 (2.6)
Type of 2nd stents (n=52) 0.001
Metal 12 (85.7) 6 (15.8)
Plastic 2 (14.3) 32 (84.2)
Type of last stents (n=52) 0.001
Metal 12 (85.7) 12 (31.6)
Plastic 2 (14.3) 26 (68.4)
Conversion to PTBD 8 (22.9) 19 (28.4) 0.55
Median internal stent patency, day 112 (77.5–143.5) 56 (7.0–201.0) 0.63

Data are presented as the number (%) or median (interquartile range).

BMS, bilateral metal stents; MPS, multiple plastic stents; PTBD, percutaneous transhepatic biliary drainage.