Skip to main content
. 2021 Jun 24;1(3):100037. doi: 10.1016/j.xjidi.2021.100037

Table 9.

Spearman’s Correlation Coefficient Matrix between the MyotonPRO Biomechanical Parameters Using Parameter Averages in all Study Patients (Combined Sclerotic cGVHD and Post-Transplant Control) for Averages across All Sites (n = 24) and Averages Across Supine Sites (n = 26)

Averages Across All Sites
Frequency Relaxation Time Stiffness Creep Decrement
Frequency 1 –0.94 0.95 –0.86 –0.28
Relaxation time –0.94 1 –0.93 0.94 0.41
Stiffness 0.95 –0.93 1 –0.82 –0.22
Creep –0.86 0.94 –0.82 1 0.54
Decrement –0.28 0.41 –0.22 0.54 1
Averages Across Supine Sites
Frequency Relaxation Time Stiffness Creep Decrement
Frequency 1 –0.94 0.95 –0.87 –0.10
Relaxation time –0.94 1 –0.94 0.94 0.15
Stiffness 0.95 –0.94 1 –0.87 –0.04
Creep –0.87 0.94 –0.87 1 0.32
Decrement –0.10 0.15 –0.04 0.32 1

Abbreviation: cGVHD, chronic graft-versus-host disease.

Higher absolute values of Spearman’s correlation coefficient represent a greater correlation between the two parameters.