Table 3.

Baseline Static Perimetry –Reliability Measures Within Test Session and Variability Among Sessions Data

Clinical Diagnosis
Overall N =126a USH2 N=80 ARRP N=46

Reliability Factor (%) b
Median (IQR)

Overall 5.1 (2.6, 8.2) 5.2 (2.1, 9.1) 5.1 (3.0, 7.3)
Test 1 4.7 (1.9, 9.0) 4.2 (1.7, 8.8) 5.1 (2.8, 9.8)
Test 2 4.7 (2.5, 9.8) 5.1 (2.4, 11.1) 4.6 (2.6, 7.2)
Test 3 5.0 (2.4, 9.0) 5.4 (2.3, 9.4) 4.5 (2.6, 8.8)

False positives rate (%) b
Median (IQR)

Overall 1 (0, 3) 1 (0, 4) 2 (0, 3)
Test 1 0 (0, 4) 0 (0, 4) 1 (0, 3)
Test 2 0 (0, 3) 0 (0, 5) 0 (0, 3)
Test 3 0 (0, 5) 0 (0, 5) 0 (0, 4)

False negatives rate (%) b
Median (IQR)

Overall 8 (3, 14) 8 (2, 15) 8 (5, 11)
Test 1 6 (3, 15) 6 (0, 13) 8 (3, 15)
Test 2 7 (3, 16) 8 (3, 19) 7 (3, 13)
Test 3 7 (3, 17) 7 (2, 17) 7 (3, 14)

Intraclass correlation coefficient (95% confidence interval) c
Overall (tests 1,2, and 3) 0.96 (0.94 0.97) Not applicable
Tests 1 and 2 0.98 (0.97 0.98) Not applicable
Tests 2 and 3 0.95 (0.93 0.97) Not applicable
Tests 1 and 3 0.94 (0.92 0.96) Not applicable

Repeatability coefficient (95% confidence interval) c
Overall (tests 1,2, and 3) 13.7 (9.2, 16.3) Not applicable
a

Static perimetry results were graded by a reading center. 1 participant in ARRP group was missing all SP tests and is excluded from this table.

b

Test 2 and Test 3 data are not included for 24 participants, respectively (22 secondary cohort participants only performed the test once, and 2 primary cohort participants were missing the second and the third test)

c

Variability analysis data are not included for 25 participants (22 secondary cohort participants only performed the test once, and 2 primary cohort participants were missing the second and the third test, and 1 participant was missing the third VTOT value.)