Comparison of accuracy of use between the 1st and 2nd assessment period of the B‐PEWS score

Period 1, n (%) Period 2, n (%) p‐value
Heart rate incorrect 130 (65.3) 106 (36.3) <0.001C
Systolic blood pressure incorrect 163 (81.9) 137 (46.9) <0.001C
Capillary refill time incorrect 28 (14.1) 9 (2.1) <0.001C
Respiratory rate incorrect 102 (51.3) 86 (29.5) <0.001C
Respiratory effort incorrect 12 (6.0) 7 (2.4) 0.055F
Oxygen saturation incorrect 24 (12.1) 15 (5.1) 0.006F
Supplemental oxygen incorrect 13 (6.5) 15 (5.1) 0.555F
Wrong recommendations used because of incorrect score 86 (43.2) 58 (19.9) <0.001F
No. of total score adequately calculated 14 (7.5) 94 (32.2) <0.001C
Use of correct age group 64 (32.2) 156 (53.4) <0.001C
No. blanks in parameters 77 (38.7) 35 (12.0) <0.001C
No. untraceable mistakes 55 (27.6) 1 (0.3) <0.001F
Adherence to ‘Assess/rescore’ in no., percentage mean (SD) 65.2 (21.1) 79.3 (16.4) <0.001W
No. of best scenario 1 (0.5) 27 (9.2) <0.001F
Average admission time in days, mean (SD) 4.8 (2.9) 4.8 (4.1) 0.319W