Skip to main content
. 2017 Feb 22;2(1):011002-1–011002-14. doi: 10.1115/1.4035918

Table 2.

Sigmoid nonlinear wall model parameters and Windkessel model outflow boundary condition parameters used for prediction of area and pressure in the ascending aorta (AA), femoral artery (FA), and carotid artery (CA). Parameter values are stated with three significant digits


Sigmoid wall model parameters

Windkessel parameters
r0 A0 Am α k A1 b1 R1 R2 C (104)
AA 0.955 2.87 4.67 82 5.5 0.467 0.1 780 950 7.54
FA 0.275 0.237 0.326 105 1.03 0.787 0.02 4798 10,815 0.740
CA 0.392 0.482 0.503 91.5 2.98 0.477 0.071 7800 15,500 0.740