Table 5. Operating Conditions Used in the Performance Calculation for the Reactor with Inert Gas Stripping.

initial FAME concentration (mol/m3) 2509
initial DEA concentration (mol/m3) 2650
initial volume of the gas (mL) 900
initial volume of the liquid mixture (mL) 100
M = total reactor volume/initial volume of liquid mixture 10
temperature (°C) 80
Keq at 80 °C (obtained from Section 4.2) 16.92
kf at 80 °C (m3/mol·min) (obtained from Section 4.2) 3.95 × 10–5
γMeOH at 80 °C (obtained from Section 4.2) 0.7
Cref, (mol/m3) = initial FAME concentration (mol/m3) 2509
Qg, (m3/min) (Qg* = 10) 9.91 × 10–5