TABLE 7.

Comparisons of the developed cELISA with commercial IDEXX ELISA kit by detecting challenged and clinical pig serum samples

Samples cELISA no. Commercial ELISA kit
Agreement (%)a Kappa valueb Positive ratec
+
Challenged sera + 208 (A) 205 (B) 3 99.2% 0.98
173 (C) 0 173 (D)
Clinical sera + 395 (A) 391 (B) 4 96.4% 0.82 87.8%
55 (C) 12 43 (D)

a Agreement (%) = (B+D) / (A+C).

b The kappa value > 0.4 was regarded as significant difference.

c Positive rate (%) = A / (A+C).