. 2000 Jan;38(1):85–89. doi: 10.1128/jcm.38.1.85-89.2000

TABLE 2.

Relationship between reported HIV-1 RNA copy numbers in terminally diluted clinical specimens and specimen input volume

Input vol (ml) No. (%) of diluted and undiluted specimensa:
Mean copy no. for specimens at the indicated dilutionb
Below lower limit of detection With HIV-1 RNA detected Undiluted Dilution 1 Dilution 2 Dilution 3 Σ
0.1 29 (24) 91 (76) 28,040 3,810 1,001 413 33,264
0.5 21 (17) 99 (83) 130,193 15,193 2,478 1,017 149,601
1.0 7 (6) 113 (94) 221,509 30,441 4,976 1,501 479,936
a

Each of 10 specimens from HIV-1-infected individuals was tested undiluted and at three serial dilutions with the NASBA HIV-1 RNA QT system. Three tests were performed on the specimens at each dilution per input volume. 

b

The dilution series for the clinical specimens were as follows. Five specimens were tested undiluted and at dilutions of 1:2, 1:5, and 1:10. Two specimens were tested undiluted and at dilutions of 1:5, 1:10, and 1:50. Three specimens were tested undiluted and at dilutions of 1:10, 1:100, and 1:10,000.