TABLE 1.
The three preset data processing functions of Tobii Pro Lab. Source: adapted from Tobii Technology (2019).
| Preset function | Raw Gaze Filter | Fixation Filter | Attention Filter |
| Description: | Extracts raw gaze samples with three pre-processing functions | Applies I-VT fixation classifier algorithm with the velocity threshold of 30°/s | Applies I-VT fixation classifier algorithm with the velocity threshold of 100°/s |
| Data composition: | Data includes all gaze samples (including all noise) | Excludes smooth pursuit and vestibulo-ocular reflex (VOR) | Includes smooth pursuit, VOR and 10–15% of saccades |
| Attention allocated to the stimulus: | Overestimated | Slightly underestimated | Slightly overestimated |
| Best suited for: | Studies focusing on mechanisms of vision and dwells | Controlled studies with only fixations and saccades | Mobile environments with movement |