Univariate Logistic Regression Models for OCTA and AO Fundus Camera Variables Depending on Confirmed CHD

Estimate OR 95% LL 95% UL P
OCTA variable
 Retinal inner ring −0.1029 0.9022 0.754 1.0428 0.2056
 Retinal outer ring −0.1207 0.8863 0.6932 1.094 0.2897
 SCP inner ring −0.1139 0.8924 0.7156 1.0646 0.2507
 SCP outer ring −0.1084 0.8972 0.6718 1.1537 0.4197
 DCP inner ring −0.0184 0.9818 0.8801 1.091 0.7238
 DCP outer ring −0.0066 0.9935 0.8756 1.1303 0.9155
 CC inner ring −0.2511 0.778 0.5523 1.0361 0.1114
 CC outer ring −0.3696 0.691 0.4497 0.9766 0.0565
 FAZ area −0.4124 0.6621 0.3407 1.2157 0.1957
AO variable
 Lumen diameter 0.0115 1.0116 0.963 1.0712 0.6609
 Total diameter 0.0088 1.0089 0.954 1.0712 0.759
 WCSA <−0.1 0.9998 0.9988 1.0008 0.6931
 WLR −0.265 0.7672 0.2477 2.1749 0.6236

The 95% LL and 95% UL represent the 95% lower and upper limits of the OR, respectively. Axial length was included as an additional independent variable in the model.