Skip to main content
[Preprint]. 2021 Nov 16:rs.3.rs-1009310. [Version 1] doi: 10.21203/rs.3.rs-1009310/v1

Table 4.

Model performance by 10-fold cross validation for ICU transfer, shock, and RRT. The sensitivity and specificity were calculated at the cut-off value of 0.5.

Outcome Statistics Lasso LR Elastic net LR XGBoost
ICU transfer Sensitivity (95% CI) 0 (0,0.08) 0.02 (0,0.12) 0.02 (0,0.12)
Specificity (95% CI) 1 (0.99,1) 1 (0.99,1) 0.92 (0.89,0.95)
AUC (95% CI) 0.6 (0.52,0.68) 0.58 (0.5,0.66) 0.51 (0.36,0.65)
Shock Sensitivity (95% CI) 0.03 (0,0.1) 0.03 (0,0.1) 0.45 (0.33,0.57)
Specificity (95% CI) 0.99 (0.98,1) 0.99 (0.98,1) 0.91 (0.89,0.94)
AUC (95% CI) 0.75 (0.68,0.83) 0.76 (0.69,0.82) 0.7 (0.58,0.82)
RRT Sensitivity (95% CI) 0.25 (0.1,0.47) 0.25 (0.1,0.47) 0.58 (0.37,0.78)
Specificity (95% CI) 0.99 (0.98,1) 0.99 (0.98,1) 0.98 (0.97,0.99)
AUC (95% CI) 0.88 (0.79,0.98) 0.88 (0.78,0.98) 0.78 (0.6,0.95)