Table 3 |.

Troubleshooting table

Step Problem Possible reason Solution
22 No mitoribosome peak appears in UV absorption Mitoribosomes exist at much lower abundance than cytosolic ribosomes. Sometimes the mitoribosome peak in UV absorption is not apparent Collect the fractions between the 40S and 60S cytosolic ribosome subunit peaks and extract RNA from all of them, or check for mitochondrial ribosomes by western blot
74 No reverse transcription product observed in gel Depending on sample input and technique during library preparation, the amount of sample can be very low at this stage. Nevertheless, even if a band is not visible, there might be enough cDNA to be amplified by PCR Proceed by cutting the desired size range
87 No targeted band observed in PCR gel Sample input at the start of the procedure might be too low, or the sample was lost during a previous step If this continues to occur, we recommend increasing sample input and analyzing sample loss at each stage to identify the problem
93 Issues in mapping and computation - Refer to the GitHub page for some common problems in the bioinformatics analysis