Skip to main content
. 2021 Nov 12;6(46):31026–31036. doi: 10.1021/acsomega.1c04135

Table 4. Temperature Distributions in the Coalbed for CCG and ECG Modes.

      TECG
Texp (°C) P (xy)a TCCG (°C) P = 400 W
800 (8.25, 15) 801 808
(8.25, 0) 802 812
(8.25, 30) 798 806
(6, 15) 799 810
(10.5, 15) 801 804
  Taverage 800.25 808
  Tsurface   852
a

Coordinates in the ECG coalbed and in the CCG coalbed are represented in Figure 11. The coordinates (8.25, 15) represent the center of the bed, and the unit is mm. TECG was measured in ECG mode with a power of 400 W, and the unit is °C.