Skip to main content
. 2021 Oct 29;9(11):1578. doi: 10.3390/biomedicines9111578

Table A7.

The results of fitting the dose–response model to the measurements of cell viability. Estimated values of the dose–response model parameters for AMS-6-Dox in 2D and 3D.

2D 3D
Estimated Value Standard Error Estimated Value Standard Error
Maximum effect, % 63.06 1.97 40.53 5.47
EC50, µg/mL 0.26 0.06 2.38 0.86
Hill coefficient 2.81 0.80 0.34 0.18
IC50, µg/mL 0.46 0.10 >10