Skip to main content
. 2021 Nov 18;13(22):5795. doi: 10.3390/cancers13225795

Table 5.

Dose constraints for organs at risk for moderate hypofractionation in 20 fractions (control arm). Rectum_adapt will be generated by delineation of the rectum in the co-registered CB-CTs, MV-CTs or MRI images of the first three fractions. Manual delineation of the Rectum_adapt should consider the mean rectal volume.

Organ Dose for 20 Fractions (Gy) Max. Volume (%)
Optimal
Max. Volume (%)
Mandatory
Rectum or Rectum Adapt Dose for 20 Fractions (Gy) Max Volume (%) Max Volume (%)
20 85
25 80
30 57
40 38 50
50 22
57 5 10
60 0.01 0.3
Bladder Dose for 20 fractions (Gy) Max volume (%) Max volume (%)
40 30 40
50 15 25
60 3 5
Femoral head left and right Dose for 20 fractions (Gy) Max volume (%)
41 50
Penile bulb Dose for 20 fractions (Gy) Max volume (%) Max volume (%)
41 50
49 20
Sigmoid Dose for 20 fractions (Gy) Max volume (%) Max volume (cc)
53 3
Small bowel Dose for 20 fractions (Gy) Max volume (cc)
41 17
47 Dmax