Modeling and Parallel Operation of Exchange-Biased Delta-E Effect Magnetometers for Sensor Arrays

Benjamin Spetzler 1,*, Patrick Wiegand 1, Phillip Durdaut 1, Michael Höft 1, Andreas Bahr 1, Robert Rieger 1, Franz Faupel 1
Editor: Iren E Kuznetsova1
PMCID: PMC8619412  PMID: 34833678

Abstract

Recently, Delta-E effect magnetic field sensors based on exchange-biased magnetic multilayers have shown the potential of detecting low-frequency and small-amplitude magnetic fields. Their design is compatible with microelectromechanical system technology, potentially small, and therefore, suitable for arrays with a large number N of sensor elements. In this study, we explore the prospects and limitations for improving the detection limit by averaging the output of N sensor elements operated in parallel with a single oscillator and a single amplifier to avoid additional electronics and keep the setup compact. Measurements are performed on a two-element array of exchange-biased sensor elements to validate a signal and noise model. With the model, we estimate requirements and tolerances for sensor elements using larger N. It is found that the intrinsic noise of the sensor elements can be considered uncorrelated, and the signal amplitude is improved if the resonance frequencies differ by less than approximately half the bandwidth of the resonators. Under these conditions, the averaging results in a maximum improvement in the detection limit by a factor of N. A maximum N200 exists, which depends on the read-out electronics and the sensor intrinsic noise. Overall, the results indicate that significant improvement in the limit of detection is possible, and a model is presented for optimizing the design of delta-E effect sensor arrays in the future.

Keywords: magnetometer, delta-E effect, sensor array, magnetoelectric, cantilever, exchange bias

1. Introduction

The detection of small amplitude magnetic fields is of interest for various fields of application, e.g., in magnetic recording, geomagnetism, and aerospace engineering [1]. Specific engineering and development challenges arise for biomedical applications, such as cell and particle mapping [2,3], magnetomyography [4,5], or magnetocardiography [6,7,8,9]. Such applications are often connected to inverse solution problems that benefit from large arrays with many sensor elements and the possibility of quick spatial field mapping [10,11]. Magnetic flux densities in this field of application are of the order of tens of picotesla and less [12] with frequency components often well below 1 kHz [5,13]. Therefore, research on sensor systems for biomedical applications is devoted to improving the minimum detectable field at low frequencies while minimizing critical parameters such as size, power consumption, and cost [13].

The gold standard for detecting such small magnetic fields is superconducting quantum interference device (SQUID) magnetometry [14,15]. These sensors must be cooled and magnetically well-shielded during operation, which makes them expensive and extensive to operate. Such setups are limited in the number of sensor elements and their minimum distance to the magnetic source. Atomic magnetometers [16,17,18] have been investigated as an affordable alternative to SQUIDs and have achieved limits of detection (LOD) in the fT/Hz regime at low signal frequencies between 1–200 Hz [16]. Despite this progress, atomic magnetometers often require magnetic shielding, and their limited CMOS integrability and downsizing reduce the number and density of sensor elements that can be used in array applications. Miniaturization and MEMS fabrication of atomic magnetometers is currently an active field of research [19,20]. Many magnetometers are being investigated to overcome such limitations [4,15], and an overview and comparison of magnetic field sensors for biomedical applications can be found [13].

In this work, we study magnetic field sensors based on magnetoelectric composite resonators. Previously, sensor systems utilizing the direct magnetoelectric effect were discussed for magnetocardiography [21] and magnetomyography [5], and limits of detection in the low and sub-pT/Hz regime have been reached with a linear response over several orders of magnitude [22]. Magnetoelectric sensors can be produced on a large scale with standard micro-electro-mechanical system (MEMS) technology and dimensions down to the micrometer range [23]. They are potentially cost-efficient, feature low power consumption, and are integrable with CMOS electronics. These aspects make magnetoelectric sensors promising candidates for sensor arrays. On the other hand, detecting small magnetic flux densities is limited to a narrow bandwidth of a few hertz around the resonance frequency, which is usually in the kilohertz regime for millimeter-sized resonators or the megahertz regime for micrometer-sized devices. Such high and narrow frequency regimes are not suitable for many applications [21]. Shifting them down increases the contributions of 1/f noise and requires large resonators with low resonance frequencies, which are susceptible to mechanical vibrations and reduce the spatial resolution.

Delta-E effect magnetometers extend the measurement range of magnetoelectric sensors and shift it to low frequencies while avoiding 1/f noise and keeping the advantages of magnetoelectric composites and the MEMS fabrication technology. In contrast to sensors based on the direct magnetoelectric effect, delta-E effect sensors benefit from high resonance frequencies because they operate on a modulation scheme. The higher resonance frequencies permit miniaturization and render the devices robust against mechanical disturbances. The modulation occurs via the magnetoelastic delta-E effect [24,25,26], i.e., the magnetization induced change of the stiffness of the material, which leads to a detuning of the resonance frequency upon the application of a magnetic field. This detuning can be measured as a change of the electrical admittance of the sensor and causes a modulation of the current through the sensor [27]. Although precursor steps towards the delta-E effect sensor concept were already made in the 1990s [28], it took another two decades until fully integrable delta-E effect sensors [29] were developed based on microelectromechanical magnetoelectric composite cantilevers [26,30,31,32,33,34], plate resonators [35,36], or other designs [37], including macroscopic laminate structures [38,39]. MEMS cantilever sensors achieved LODs < 100 pT/Hz in the frequency range from approximately 10–100 Hz [32]. This is currently of a similar order of magnitude as the LODs of some magnetoresistive sensors [40,41]. As an application example of delta-E effect sensors, magnetic particle mapping was recently demonstrated for cell localization [42]. In this setup, the sensor was operated under a magnetic bias field provided by a permanent magnet. Most studies rely on an external magnetic bias field to operate the sensor at an optimum signal-to-noise ratio. Instead of a permanent magnet, the magnetic bias field is often created with external coils. For delta-E effect sensor arrays with many sensor elements, coils and permanent magnets can be inconvenient because their stray fields shift the operation points of adjacent sensor elements, and the additional electrical components increase the volume of the sensor system.

Recently, we demonstrated a first delta-E effect magnetometer based on exchange biased magnetic multilayers that circumvents such complications and still achieves a minimum detection limit of 350pT/Hz at 25 Hz [34]. The exchange bias provides an internal bias field and thereby paves the way to flexible and compact delta-E effect sensor arrays with many sensor elements. Only recently were sensor arrays based on magnetoelectric sensor elements reported [43,44,45,46,47], and were limited to direct magnetoelectric detection and were mostly based on macroscopic resonators. A CMOS integrated array of magnetoelastic sensor elements was presented for vector magnetometry [48], but the sensor elements were only characterized individually and without a signal and noise analysis. No attempts of parallel operating delta-E effect sensor elements in array configurations or thorough signal and noise analyses of such have yet been presented.

In this study, we explore the operation of delta-E effect sensor elements in arrays to improve the signal, noise, and limit of detection. Instead of measuring the magnetic field at different locations, spatial resolution can be sacrificed by averaging the outputs of several sensors operating simultaneously. However, the large number of hardware channels required to achieve the desired improvement in the LOD increases the size of the setup and limits the number and density of sensors. As a solution, sensor elements are connected in parallel and operated and read out simultaneously with one set of electronics. This method of parallel operation is accompanied by other complications, and they are analyzed here to identify the potential of such a setup. After presenting the sensor system, which is based on exchange-biased delta-E effect sensors, a signal-and-noise model is developed and validated with measurements. The model is used to analyze the sensor characteristics as functions of the number of sensor elements and variations in the resonance frequency that can occur during fabrication. Implications for the design of delta-E effect sensor arrays are derived and requirements on the reproducibility are identified and discussed.

2. Sensor System

In this study, two MEMS fabricated sensor elements are used, based on 50 µm thick poly-Si cantilevers with a length of 3 mm and a width of 1 mm. They are covered with a 4 µm thick exchange-biased magnetic multilayer [49] and a 2 µm thick piezoelectric AlN layer [50] on the top. The AlN layer is contacted via two Ta-Pt electrodes on its top and rear-side for excitation and read-out. The magnetic multilayer is based on alternating antiferromagnetic Mn70Ir30 (8 nm) and soft ferromagnetic Fe70.2Co7.8Si12B10 (200 nm) layers. In this configuration, the antiferromagnetic layer provides an exchange bias that serves as an internal bias field for the ferromagnetic layer to ensure a nonzero sensitivity without an externally applied magnetic field. Hence, all measurements shown in this study are performed without a magnetic bias field. Details about the layer structure and fabrication process and a comprehensive analysis of sensors with a similar geometry can be found elsewhere [34]. Two sensor elements are mounted on a printed circuit board, respectively, as shown in Figure 1. They are connected in parallel to each other and connected to the input of a low-noise JFET-based charge amplifier [51]. A high-resolution A/D and D/A converter (Fireface UFX+, RME, Chemnitz, Germany) is used for excitation and read-out (24 bit, 32 kHz). For the measurements, the sensors are placed in a magnetically and electrically shielded setup [52], based on a mu-metal shielding cylinder (ZG1, Aaronia AG, Strickscheid, Germany), and are located in a copper fleece coated box that is mechanically decoupled to reduce the impact of mechanical vibrations. All magnetic flux densities are applied along the long axis of the cantilever.

Figure 1.

Figure 1

(a) Example sensor (without encapsulation) used in this study; it comprises a MEMS-fabricated cantilever resonator as a sensing element mounted on a printed circuit board (PCB). The JFET charge amplifier on the PCB was used in a previous study and is bypassed here and replaced by an external one. (b) Brass encapsulation for mechanical protection and electrical shielding during the measurements. Further details are reported in Ref. [34].

3. Array Modeling

In an alternating magnetic field, the delta-E effect causes an oscillation of the mechanical stiffness of the cantilever. The response of the cantilever to this stiffness change is damped with increasing magnetic field frequencies because of its mass inertia. Previously, this behavior was modeled with a first-order Bessel filter [27,53], applied to the demodulated simulated output signal of the charge amplifier. Later, a dynamic sensitivity was introduced [54] to consider the low-pass filter characteristics of the sensor as a function of the magnetic field frequency. The dynamic sensitivity was derived from the frequency response of a simple damped harmonic oscillator; however, it is only fully valid if the sensor is excited at its mechanical resonance frequency. For many previously analyzed sensors [33,53,55], this approximation was well justified, as their resonance frequency was close to their optimum excitation frequency, i.e., the excitation frequency with the largest signal-to-noise ratio. This is not a general property of such sensors but depends on their geometry, material, and electrical capacitance. Significant quantitative and qualitative deviations between measurements and simulations can occur if the excitation is not in mechanical resonance [56] (p. 139). In an array, not all sensor elements can be excited in mechanical resonance because of variations in their resonance frequencies that occur during fabrication. In this section, a signal and noise model is developed based on an altered approach, and it permits describing the output signal of an array of N sensor elements excited at an arbitrary excitation frequency.

3.1. Signal Model

During operation of the sensor array, a sinusoidal voltage uex(t) with amplitude u^ex and frequency fex is applied. It excites the magnetoelectric resonators of each sensor element at, or close to, its respective resonance frequency fr,n. In linear approximation, the voltage at the charge amplifier’s output can be described by:

uco(t)Zf(fex)·is(t). (1)

In this equation, the time is denoted by t and the feedback impedance of the charge amplifier by Zf. The current is through the array of parallel-connected sensor elements can be expressed as the sum of all individual currents is,n that flow through the respective sensor element n. To describe is,n, we use a modified Butterworth-van Dyke (mBvD) equivalent circuit representation, illustrated in detail in Appendix A. It consists of a series resonant circuit with a resistance Rr,n, inductance Lr,n, and capacitance Cr,n that consider the resonant behavior of the cantilever. The electrodes of each sensor element form a capacitor with the piezoelectric layer. It is described by a capacitance Cp,n and resistance Rp,n, both in parallel to the series LCR-circuit. Further, the current is,n can be separated into a current ir,n, which passes through the resonant LCR circuit, and a current ip,n, which passes through the parallel pathway. A sketch of the circuit model is provided in Figure A1 (Appendix A). For N parallel-connected sensor elements, is can be described by:

is(t)=n=1Nis,n=n=1N(ip,n+ir,n) . (2)

The current ip,n is described as a function of the magnitude |Yp,n| and the phase angle ϕp,nangle{Yp,n} of the electrical admittance Yp,n of the parallel pathway, and results in:

ip,n=u^ex·|Yp,n(fex)|·cos(2πfext+ϕp,n(fex)). (3)

This current is independent of the magnetic field, and the corresponding electrical admittance Yp,n(f)=Rp,n1+2πfCp,n as a function of frequency f is entirely determined by the capacitance Cp,n of the respective piezoelectric layer-electrode configuration and its resistance Rp,n. Similarly, the current ir,n can be described as a function of the magnitude |Yr,n| and the phase angle ϕr,nangle{Yr,n} of the magnetic-field and frequency-dependent admittance Yr,n of the resonant circuit of a sensor element n. The current ir,n is filtered in the time domain to consider the frequency response of the resonator. We use a second-order digital peaking (resonator) filter with a rational transfer function r that is determined by the resonance frequency fr and the quality factor Q (Appendix B). It is given by:

ir,n=r{u^ex·|Yr,n(fex,B,t)|·cos(2πfext+ϕr,n(fex,B,t))}.  (4)

In contrast to ip,n, the resonant current ir,n depends on the magnetic flux density B=B0+Bac(t), which can be expressed as a static magnetic flux density B0, superposed by a small, time t dependent contribution Bac(t). For small amplitudes B^ac of Bac(t), the admittance Yr,n(f,B) around B0 and at f = fex can be approximated by a first-order Taylor series:

|Yr,n(fex,B,t)||Yr,n(fr,B0)|+d|Yr,n(f,B0)|df|f=fexdfr,n(B)dB|B=B0·Bac(t), (5)

and

ϕr,n(fex,B,t)ϕr,n(fr,B0)+dϕr,n(f,B0)df|f=fexdfr,ndB|B=B0·Bac(t). (6)

Because the damping of the carrier relative to its maximum value at fex=fr is already considered by r, the zero-order element in the series expansion is taken at f=fr instead of f=fex. If not stated differently, we always use B0=0 because the exchange bias sensors used here do not require an externally applied magnetic bias field.

3.2. Definition of Sensitivities

The derivatives in the previous two equations describe the influence of the magnetic field on the electrical admittance and can be referred to as sensitivities. A magnetic sensitivity can be defined as:

Smag,n=dfr,ndB|B=B0 , (7)

and two electrical sensitivities Sel,am,n and Sel,pm,n as:

Sel,am,n=d|Yr,n(f,B0)|df|f=fex,Sel,pm,n=dϕr,n(f,B0)df|f=fex. (8)

These definitions of electrical sensitivities differ from previous work [26,53,57], which is further discussed at the end of this section. A normalization, as in Refs. [26,57], is still required to compare the electric and magnetic sensitivity of sensors with different resonance frequencies. After amplification by the charge amplifier, the output signal uco(t) is fed into a quadrature amplitude demodulator to obtain the demodulated signal u(t). The amplitude spectrum U^(f) of u(t) can then be used to define the voltage sensitivity SV(f) as a normalized measure for the sensor’s signal response:

SV(fac)=U^(fac)B^ac with [SV]=VT . (9)

The voltage sensitivity SV(fac) can be estimated by applying a sinusoidal magnetic test signal Bac=B^acsin(2πfact), with well-defined amplitude B^ac and frequency fac, to obtain U(fac) from the measurement. With SV(fac), a measure for the smallest detectable magnetic field can be defined. This measure is frequently referred to as limit of detection (LOD) [22,27], equivalent magnetic noise [58,59], or detectivity [40]:

LOD(fac)=E(fac)SV(fac) with [LOD]=THz , (10)

where E(fac) is the voltage noise density of u(t) at fac, after demodulation and measured without any magnetic field applied. The response of Delta-E effect magnetometers to magnetic fields depends on the mutual orientation of the magnetic field and sensor element. Consequently, the sensitivities and LOD (Equations (7)–(10)) are generally functions of the orientation of the magnetic field. Details about the signal-and-noise characterization of E-effect magnetometers can be found elsewhere [27,53,54].

The definitions of the electrical sensitivities (Equation (8)) differ from previous formulations [26,53,57] limited to the special case of one sensor element excited in resonance (fex=fr). The electrical sensitivities defined within those models use the total sensor admittance YsYr+Yp instead of Yr to form the derivatives with respect to the frequency. Here, the parallel admittance Yp is considered in the total sensor current is. This definition arises naturally from separating the sensor current into the resonator current and the current though the capacitor, and it is used to consider the response of the resonator to the alternating magnetic field.

3.3. Noise Model

In the following, we modify and extend the model presented in Ref. [54] to analyze the noise of the array sensor system and how it is influenced by adding parallel sensor elements. Additional sensor elements are considered and minor noise sources, e.g., of the cables, are omitted. The equivalent circuit noise model is shown in Figure 2 and a summary of the parameters is given in Table A1 in Appendix C. The noise of the excitation source is described by a thermal-electrical noise source Eex of the D/A converter’s output resistance Rex and the D/A converter’s quantization noise EVex. Similarly, EAD describes the noise that occurs during the analog-digital conversion. The noise source of the JFET charge amplifier is calculated from the model in [51] and is summarized in EJCA. Each sensor element of the array is described by the mBvD equivalent circuit (Figure 2b). For the sensor intrinsic noise of the nth sensor element, we consider the thermal-electrical noise source Ep,n of the piezoelectric layer and the thermal-mechanical noise source Er,n of the resonator. The value of the thermal-electrical noise sources can be calculated from:

Ex=4kBTRx with x {ex,p,r}, (11)

with Boltzmann’s constant kB=1.38×1023J/K and the temperature T=290 K. The noise source EVex and EAD were obtained from measurements. Here, we consider small excitation amplitudes u^ex<100 mV only and obtain EVex=26.8 nV/Hz and EAD=6.9nV/Hz in this case. Each noise source is transformed to the output of the charge amplifier to analyze its contribution to the total noise density at the charge amplifier’s output. To simplify the final expressions, the following impedances are defined. The impedance Zs,n of the nth sensor is obtained from:

Zs,n=Zr,nZp,n , (12)
Zr,n=Rr,n+jωLr,n+1jωCr,n , (13)
Zp,n=1jωCp,nRp,n , (14)

where || denotes the parallel operator (a||b = (a−1 + b−1)−1).

Figure 2.

Figure 2

(a) Noise model of the sensor system comprising an excitation source, charge amplifier, and N sensor elements Sn with impedances ZSn, connected in parallel. (b) Equivalent circuit noise model of each sensor element Sn, with resonator intrinsic noise source Er,n and piezoelectric noise source Ep,n.

The total impedance of all N sensor elements connected in parallel is:

Zs=[n=1NZs,n1]1 . (15)

The impedance ZC2 of the cable with capacitance CC2 and resistance RC2 between the sensor elements and the charge amplifier is given by:

ZC2=1jωCC2RC2, (16)

and the feedback impedance of the charge amplifier by:

Zf=1jωCfRf, (17)

with the capacitance Cf and the resistance Rf. The total voltage noise density at the output of the charge amplifier is obtained from the superposition of the individual output referred noise sources,

Eco2=Eco,JCA2+Eco,Vex2+Eco,AD2+Eco,s2 , (18)

Eco,JCA of the charge amplifier, Eco,Vex of the D/A converter, Eco,AD of the A/D converter, and the contribution Eco,s of the parallel sensor elements. These noise contributions are given by:

Eco,JCA2=EJCA2|1+ZfZs+ZC2|2 , (19)
Eco,Vex2=EVex2|ZfZs|2 , (20)
Eco,AD2=EAD2 , (21)
Eco,s2=n=1N(Er,n2|ZfZr,n|+Ep,n2|ZfRp,n|) Eco,r2+Eco,p2. (22)

4. Characterization and Validation of the Signal-and-Noise Model

In this section, the sensor elements and the array are characterized regarding their impedance, signal, and noise as well as their frequency response. The measurements are compared with simulations to demonstrate the validity of the model. Details on the implementation of the model are given in Appendix D.

4.1. Electrical Sensitivity and Admittance Characterization

To eventually compare simulations with measurements, the admittance of the sensor elements is characterized. Measurements of the admittance magnitude |Ys| as functions of frequency f are shown in Figure 3a (top) for the two sensor elements S1, S2, and both connected in parallel (S1||S2). All measurements were made at B0=0 and an excitation voltage amplitude of u^ex=10 mV. An mBvD equivalent circuit as described earlier and illustrated in Appendix A is fitted to the magnitude data. The parameters obtained from the fit are given in Table A1 in Appendix C. From the mBvD parameters, we obtain resonance frequencies of fr,1=7674.9 Hz and fr,2=7676.5 Hz and quality factors of Q1=642 and Q2=558 (equations in Appendix A). This results in resonator bandwidths fBW,nfr,n/Qn of fBW,1 12 Hz and fBW,214 Hz. Hence, the difference in resonance frequencies fr=|fr,2fr,1|=1.6 Hz is significantly smaller than the bandwidth of the sensor elements.

Figure 3.

Figure 3

(a) Top: magnitudes |Ys| of the admittance of the sensor elements S1, S2 and both connected in parallel (S1||S2) measured at an applied magnetic flux density of B = 0 and an excitation voltage amplitude of u^ex=10 mV, compared with a modified Butterworth-van Dyke (mBvD) equivalent circuit fit; middle: magnitude |Yr| of the electrical admittance of the LCR series circuit of the mBvD model; bottom: derivative of |Yr| with respect to the frequency f, which we refer to as electrical amplitude sensitivity. (b) Top: corresponding phase angles ϕs of the sensor elements obtained from the mBvD model; middle: phase angles ϕr of the admittance of the LCR series circuits; bottom: their derivates, which we refer to as electrical phase sensitivities.

With the mBvD parameters, the phase angle ϕs,n is calculated and plotted in Figure 3b (top). It shows the typical minimum of an electromechanical resonator that is caused by the superposition of the current through the resonator and the current through the parallel capcitance Cp,n and resistance Rp,n. The values of Ys,n and ϕs,n are similar to other electromechanical resonators that have been operated as delta-E effect sensors (e.g., [32,34,54]). Hence, the chosen sensor elements are representative examples. The admittance magnitude |Yr,n| and phase angle ϕr,n of the series resonance circuit are obtained from the mBvD model by omitting the parallel current ip,n and are plotted in Figure 3a,b (middle). They exhibit the behavior expected from a linear resonator and the main difference between the two sensor elements is the small difference in their resonance frequencies. The electrical sensitivities Sel,am,n and Sel,pm,n are calculated following the definitions in Equation (8) from the derivaties of |Yr,n| and ϕr,n with respect to the frequency. They are plotted in Figure 3a,b (bottom). Both sensor elements have similar electrical sensitivities with extrema of Sel,am,1maxSel,am,2max±0.15 µS/Hz and Sel,pm,1maxSel,pm,2max8.5°/Hz. Note that Sel,am,n=0 at fex=fr,n, but Sel,pm,n=Sel,pm,nmax. Because the two sensor elements have very similar resonance frequencies, their total electrical admittance Ys=Ys,1+Ys,2 in parallel connection (S1||S2) shows qualitatively the same behavior but with a much increased admittance magnitude and electrical amplitude sensitivity by approximately a factor of two compared to the single sensor elements. The corresponding plots are shown in Figure 3. Comparing the magnitude and phase of Ys(S1||S2) emphasizes that an improvement in the sensitivity is only expected for the electrical amplitude sensitivity Sel,am, because the magnitudes |Yr,n| add up. In contrast, the electrical phase sensitivity Sel,pm does not improve, as it results from averaging Sel,pm,1 and Sel,pm,2. For a more comprehensive and general discussion, signal and noise must be considered and, in particular, their dependencies on the magnetic field frequency and the differences in resonance frequency. For that, the signal model is validated in the following section.

4.2. Frequency Response of the Sensor

The electrical sensitivities and sensor parameters found in the previous section are used here in the signal model and the simulations are compared with measurements. In Figure 4a, the spectrum U^co of the modulated signal is shown from a measurement of the sensor element S1 (top) and S1||S2 (bottom) using an excitation signal with a voltage amplitude of u^ex=25 mV, a frequency fex=7680 Hz and a sinusoidal magnetic test signal with an arbitrarily chosen frequency of fac=5.8 Hz, and an amplitude of B^ac=1 µT. Besides the carrier peak at fex, both spectra show one pair of peaks at fex±fac, which corresponds to the modulating signal caused by the magnetic field. Following the magnitude-frequency response of the transfer function of the resonator, the side peak closest to the resonance frequency at fr,1=7674.9 Hz (S1) is the largest. The signal model fits the measurements very well for magnetic sensitivities of Smag,1Smag,2=24 Hz/mT. Considering the normalization required for a comparison [26,57], Smag,n/fr,n is in the typical range expected from similar sensor elements [34,57].

Figure 4.

Figure 4

Comparison of simulations with measurements. (a) Example amplitude spectrum of the measured and simulated output signal using only the sensor element S1 (top) and both sensor elements in parallel S1||S2 (bottom) (u^ex=25 mV). (b) Magnitude |r| of the transfer function r of the resonator used to indicate several excitation frequencies fex by fex,1 fexfr,1, relative to the resonance frequency fr,1=7674.9 Hz of the sensor element S1 (top), and fex,2 fexfr,2, relative to the resonance frequency fr,2=7676.5 Hz  of the sensor element S2 (bottom). (c) Measured and simulated voltage sensitivity SV (Equation (9)) as a function of the magnetic field frequency fac for the excitation frequencies indicated in (b) for the sensor element S1 (top) and both sensor elements in parallel S1||S2 (bottom) (u^ex=10 mV).

Several fexfr are chosen to analyze the sensor’s magnitude-frequency response for operating out of resonance. They are indicated in Figure 4b for S1 (top) and S1||S2 (bottom) as the difference fex,1 fexfr,1 of fex to the resonance frequency fr,1 of S1, and the difference fex,2 fexfr,2 of fex to fr,2, respectively. For each excitation frequency, the voltage sensitivity SV as a function of the magnetic field frequency fac was measured four times, averaged, and plotted in Figure 4c. As expected, the measurements of both configurations (S1 and S1||S2) show qualitatively the same behavior. For excitation frequencies close to fr, the sensor’s voltage sensitivity SV exhibits a low-pass behavior with a maximum voltage sensitivity at the lowest magnetic field frequency fac.

With an increasing deviation of fex from fr, the maximum shifts to larger values of fac and further reduces its value. The reduction of the voltage sensitivity is caused by a change of the electrical sensitivities as well as the transfer function of the resonator. The model matches the measurements well with deviations mostly smaller than a factor of two and well within the estimated errors of the measurements. In line with the estimation based on the electrical sensitivity in the previous section, the simulations, and measurements of S1||S2, show an overall improved voltage sensitivity compared to S1. A more detailed analysis of this is given in Section 5, where the model is used to estimate the influence of a resonance mismatch for otherwise identical sensor elements.

4.3. Validation of the Noise Model

We omit the effect of u^ex on the quality factor and noise floor for the small u^ex used in this work, in line with previous investigations [53,54]. Noise measurements are performed for u^ex=0, i.e., the sensor’s input is shortened to ground potential, and data are recorded for 5 min with a sample rate of 32 kHz. The measured noise density spectra are compared with the simulations in Figure 5. The contributions of the sensor intrinsic thermal-mechanical noise Eco,r, and piezoelectric thermal-electric noise Eco,p, as well as the operational amplifier’s noise Eco,JCA, are shown. The measurements and simulations match well and show what is expected for no excitation, or small excitation amplitudes. Thermal-mechanical noise dominates the noise floor around the resonance frequency and, further away, thermal-electrical noise of the piezoelectric resistance. The maximum noise density peak in Figure 5 is increased by a factor of approximately 1.3 compared to the single sensor elements. This is slightly less than the maximum increase by a factor of 2 expected from Equation (22), and it is likely caused by the resonance mismatch.

Figure 5.

Figure 5

Comparison of the simulated and measured total voltage noise density Eco (Equation (18)) around the sensor’s resonance frequency. The simulated contributions of the thermal-mechanical noise density Eco,r, the thermal-electrical noise density Eco,p of the piezeoelectric layer, and the operational amplifier’s noise density Eco,JCA are shown as well. Measurements and simulations are compared for a sensor system with (a) a single sensor element S1, (b) a single sensor element S2, and (c) two sensor elements connected in parallel (S1||S2).

5. Implications for Sensor Arrays

5.1. Influence of the Number of Sensor Elements

The noise model is used to estimate the influence of the number N of sensor elements on the minimum detectable magnetic flux density. First, we consider the ideal case of identical sensor elements described with the mBvD parameters of the sensor S1. In this case, the signal magnitude increases linearly with N. The change of the total voltage noise density is less trivial because the various noise contributions depend differently on N. A simulation of the voltage noise density at the resonance frequency is shown in Figure 6 as a function of N. While the sensor intrinsic thermal-mechanical noise and thermal-electrical noise increase N, the noise of the JFET charge amplifier is N. This linear relationship can be explained with the expression for the noise gain |1+Zf/(Zs+ZC2)| of the amplifier in Equation (19). According to this expression, the noise gain is in good approximation (ZsZC2,1) inversely proportional to the impedance Zs of the array. Each additional sensor element increases the capacitance and reduces Zs (Equation (15)), and therefore, the noise gain increases linearly with N if all sensor elements are identical. The thermal-mechanical noise and the thermal-electrical noise of the amplifier dominate the noise floor at different N owing to their different dependencies on N. At small N, the thermal-mechanical noise dominates the noise floor and the LOD 1/N can be improved by adding sensor elements. At large N, the noise contribution of the amplifier dominates and no improvement in the LOD can be achieved because signal and noise are both N. A transition region exists at intermediate values of N where the improvement in LOD decreases continuously with N. This transition region is approximately around N=200Nmax for the set of sensor parameters considered.

Figure 6.

Figure 6

(a) Simulation of the voltage noise density at the resonance frequency as a function of the number N of the parallel connected sensor elements. Below approximately N=200, the noise level is dominated by the sensor intrinsic thermal-mechanical noise and increases N. At approximately N>Nmax200, the noise of the charge amplifier dominates the noise floor and is N. No significant improvement in the signal-to-noise ratio is expected for N>Nmax200 because the signal amplitude increases  N as well. (b) Simulated gain SV/SV,1 in the voltage sensitivity SV of a system with two parallel connected sensor elements relative to the voltage sensitivity SV,1 of a single sensor element as a function of the difference fr in their resonance frequencies, normalized to the bandwidth fBWfr/Q of the resonator. Examples are shown for three different parallel capacities, expressed as multiples of the parallel capacitance Cp,1 of the sensor element S1. The minima are indicated with red dots.

5.2. Influence of Resonance Frequency Mismatch

The reproducibility of sensor elements can be considerably impaired by the relaxation of small stress during fabrication [60] and by small variations in the resonator geometry. The condition fex=fr cannot be fulfilled simultaneously for all N sensor elements because both mechanisms cause a distribution in resonance frequency fr. At this point, it remains unclear to what extent such a distribution impairs signal, noise, and LOD. However, knowing the tolerable variation in resonance frequency is important for the design of sensor arrays because it imposes limitations on the resonator geometry and on the tolerances of the fabrication process.

First, the voltage sensitivity SV is calculated as a function of the resonance frequency mismatch because it must be known to estimate the LOD (Equation (10)). The model sensor system considered comprises two sensor elements connected in parallel. Both sensor elements have identical resonance frequencies and sensitivities, and they are described by the same set of mBvD equivalent circuit parameters of the sensor element S1. The resonance frequency fr1/LrCr of one sensor element is altered by increasing the mBvD parameters Lr and Cr in equal ratios. This keeps the quality factor QLr/Cr constant (Appendix A), and it causes only a negligible change in the bandwidth for the range of resonance frequencies tested. For each difference fr in the two resonance frequencies, we simulate the output signal using a magnetic test signal with a frequency of fac=1 Hz, and calculate the voltage sensitivity SV (Equation (9)). This procedure is repeated for three different example capacities Cp with values that are multiples of the parallel capacitance Cp,1 of the sensor element S1. We define the sensitivity gain SV/SV,1 by the voltage sensitivity SV of the two parallel sensor elements, normalized to the voltage sensitivity SV,1 of the single sensor element. The results are plotted in Figure 6b as functions of fr normalized to the bandwidth fBW=fr/Q of S1.

For all three values of Cp, the sensitivity gain reaches a maximum value of SV/SV,1=2, when the resonance frequencies are identical fr/fBW=0. It decreases to a minimum of around SV/SV,1=1 at roughly fr/fBW=0.5, indicated in Figure 6b with red dots. For larger fr/fBW, SV/SV,1 increases slightly but it does not reach its maximum value again. The influence of the parallel capacitance Cp on SV/SV,1 is distinct but it does not change the curves qualitatively in the considered range. A larger Cp reduces SV/SV,1 at high fr/fBW and shifts the location of the minimum to a larger fr/fBW; hence, it slightly broadens the peak around the maximum of SV/SV,1. Consequently, the condition of approximately fr/fBW<0.5 (depending on Cp) should be fulfilled to increase the signal magnitude in an array with two sensor elements. This condition can be expressed as:

fr,BWfrfBWfrfr ·Q<0.5 . (23)

The simulations in Figure 6b demonstrate that Equation (23) is not a strict criterium because the locations of the minima on the fr,BW-axis vary by up to 50% for different tested values of Cp (e.g., for Cp=2Cp,1 the minimum is at fr,BW0.75). The exact location of the minimum depends on the contribution of the current through the LCR pathway to the total sensor current, relative to the capacitive contribution of Cp. For all practical purposes, these two contributions can hardly be varied independently because changing the parallel capacitance is accompanied by a change of the excitation efficiency, e.g., by altering the electrode geometry [32] or the piezoelectric material [33].

Not only for the voltage sensitivity, but also the sensor intrinsic thermal-mechanical noise referred to as the output follows the transfer function of the resonator; this is demonstrated with the measurements and simulations in Figure 5. Therefore, the LOD is constant if the sensor intrinsic thermal-mechanical noise dominates the noise floor, which is typically fulfilled for excitation frequencies fex within the bandwidth of the resonator and sufficiently small magnetic field frequencies fac. This conclusion is in line with other experimental results [55] (Figure 6) and does still hold for two parallel operating sensor elements with different resonance frequencies. Consequently, it is also LOD(fr,BW)=const. if the thermal-mechanical noise dominates the voltage noise density at fex+fac. The frequency band around the resonance frequency where the LOD is constant depends on the difference between the thermal-electric noise level and the resonance-amplified thermal-mechanical noise level and changes with N. For the sensors analyzed, this range is approximately <fBW around fr, as shown in Figure 5.

6. Discussion and Conclusions

The signal-and-noise model developed matches well with measurements on exchange-biased sensor elements operated separately and in parallel in a setup with a single oscillator and amplifier. The model does still hold for excitation frequencies out of resonance and more than one sensor element. Hence, two major limitations of previous models have been solved and a tool is presented that can further support the design of delta-E effect sensors and sensor arrays. From the good match of the model and consistency with noise measurements, we find that the sensor intrinsic noise in our setup can be considered as uncorrelated, despite the parallel connection of sensor elements and their operation and read-out by a single oscillator and single amplifier. This is an essential precondition for improving the sensor performance by operating in parallel while using fewer electronic elements to keep the setup compact. Additional requirements were identified, which must be fulfilled to improve the signal and the limit of detection by operating many sensor elements in parallel. For the given sensor system, no significant improvement in the limit of detection can be achieved if a maximum number Nmax200 of sensor elements is exceeded. Above this number, the noise contribution of the amplifier dominates the noise floor and increases, like the signal amplitude N. Below, the sensor intrinsic noise dominates around the resonance and increases merely N, which results in LOD1/N. With the given Nmax, this would correspond to an LOD improvement by a factor of approximately 14. The value of Nmax depends on the contribution of the thermal-mechanical noise relative to the thermal-mechanical noise. Therefore, Nmax can potentially be improved by reducing the noise contribution of the charge amplifier. The proportionalities found do only hold strictly if all sensor elements are identical. Simulations of the voltage sensitivity confirmed that the improvement in signal amplitude depends significantly on the difference in the resonance frequencies of the sensor elements. It vanishes at a bandwidth normalized resonance frequency difference of approximately fr,BW0.5, depending on the value of the parallel capacitance of the sensor element. Consequently, a large signal improvement by parallel operation requires tight tolerances on the resonance frequency and, therefore, on the reproducibility provided by the fabrication process. Because the sensor intrinsic noise follows the same resonator transfer function as the signal, we expect the LOD to be constant with fr,BW for sufficiently small fr,BW, and here at approximately fr,BW<2. This value depends on the level of the thermal-mechanical noise, relative to the thermal-electrical noise of the piezoelectric layer and the noise contribution of the amplifier.

In conclusion, a model was presented that overcomes previous limitations and can be used to explore the signal and noise characteristics of delta-E effect sensor arrays. The results from measurements and simulations indicate that large arrays of parallel operating sensor elements can be an option to improve the signal and limit of detection in the future.

Acknowledgments

The authors gratefully thank Christine Kirchhof for the fabrication of the sensor elements.

Appendix A. Equivalent Circuit Model

The equivalent circuit model used to describe the electrical admittance of each sensor element is illustrated in Figure A1a and the structure of the modeled sensor array in Figure A1b.

Figure A1.

Figure A1

Illustration of (a) the modified Butterworth-van Dyke equivalent-circuit model used to describe the sensor elements, with the current ir,n through the resonator LCR-circuit and ip,n as the parallel capacitive pathway, and (b) all N parallel-connected sensor elements of the array, with the current is,n through the nth sensor element and the total current is through the array.

The following equations are used to estimate the resonance frequency fr,n and the quality factor Qn of the nth sensor element:

Qn=1Rr,nLr,nCr,n , (A1)

and

fr,n=12πLr,nCr,n . (A2)

Appendix B. Transfer Function of the Resonator

The frequency response of the resonator is modeled as second-order infinite impulse response (IIR) peaking filter with the transfer function r(z) [61]:

r(z)=n1+n2z1+n3z2d1+d2z1+d3z2 , (A3)

and the components ni of the numerator coefficients as well as di of the denominator coefficients, which are functions of the quality factor Q and the resonance frequency fr [62]:

n=(1g0g1) ,  d=(1g2g·cos(πfr)2g1) .  (A4)

To ensure a gain of −3 dB at the bandwidth, the factor g is set to:

 g=[1+2·tan(π2frQ)]1  . (A5)

Appendix C. System Parameters

In the following Table A1, the model parameters of the sensor system and the equivalent circuit parameters of the two sensor elements S1 and S2 are summarized.

Table A1.

Parameters of the equivalent circuit noise model and the modified Butterworth-van Dyke (mBvD) model.

Component Parameter Value Parameter Value
Excitation Rex 75 Ω
Cable C1 RC1 147 MΩ CC1 208 pF
Cable C2 RC2 184 MΩ CC2 36 pF
Sensor element S1 Rp,1 295 MΩ CME,1 47.157 pF
Rr,1 663.47 kΩ Cr,1 48.725 fF
Lr,1 8.826 kH fr,1 7674.9 Hz
Sensor element S2 Rp,2 310 MΩ CME,2 48.568 pF
Rr,2 755.96 kΩ Cr,2 49.112 fF
Lr,2 8.753 kH fr,2 7676.4 Hz
Amplifier Rf 5 GΩ Cf 30 pF

Appendix D. Implementation of the Model

The equations, which describe the signal-and-noise model (Equations (1)–(22)), are implemented in MATLAB (The MathWorks, Inc., Natick, MA, USA). The voltage at the charge amplifier’s output uco(t) is calculated in the time domain using Equations (1)–(6), and the electric sensitivities (Equations (7) and (8)) obtained from the impedance measurements in Section 4.1. Estimated magnetic sensitivities of Smag,1Smag,2=24 Hz/mT are used, which is in the typical range expected from similar sensor elements [34,57]. The simulated time domain signal is demodulated with a quadrature amplitude demodulator and subsequently converted to the frequency domain using Welch’s method [63]. From the power spectral density estimate, we calculate the amplitude spectrum U^(f) of the demodulated signal u(t) and the voltage sensitivity following the definition provided by Equation (9). For the noise simulations, Equations (11)–(22) are implemented to obtain the voltage noise density at the output of the charge amplifier in the frequency domain.

Author Contributions

Conceptualization, B.S.; methodology, B.S. and P.D.; formal analysis, B.S. and P.W.; investigation, B.S., P.W. and P.D.; data curation, B.S. and P.W.; writing—original draft preparation, B.S.; writing—review and editing, B.S., P.W., P.D., M.H., A.B., R.R. and F.F.; visualization, B.S.; project administration, M.H., A.B., R.R. and F.F.; funding acquisition, M.H., A.B., R.R. and F.F. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the German Research Foundation (DFG) via the collaborative research center CRC 1261.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on reasonable request from the corresponding author.

Conflicts of Interest

The authors declare no conflict of interest.

Footnotes

Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Lenz J., Edelstein S. Magnetic Sensors and Their Applications. IEEE Sens. J. 2006;6:631–649. doi: 10.1109/JSEN.2006.874493. [DOI] [Google Scholar]
  • 2.Gleich B., Weizenecker J. Tomographic Imaging Using the Nonlinear Response of Magnetic Particles. Nature. 2005;435:1214–1217. doi: 10.1038/nature03808. [DOI] [PubMed] [Google Scholar]
  • 3.Friedrich R.-M., Zabel S., Galka A., Lukat N., Wagner J.-M., Kirchhof C., Quandt E., McCord J., Selhuber-Unkel C., Siniatchkin M., et al. Magnetic Particle Mapping Using Magnetoelectric Sensors as an Imaging Modality. Sci. Rep. 2019;9:2086. doi: 10.1038/s41598-018-38451-0. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Cohen D., Givler E. Magnetomyography: Magnetic Fields around the Human Body Produced by Skeletal Muscles. Appl. Phys. Lett. 1972;21:114–116. doi: 10.1063/1.1654294. [DOI] [Google Scholar]
  • 5.Zuo S., Schmalz J., Özden M.-Ö., Gerken M., Su J., Niekiel F., Lofink F., Nazarpour K., Heidari H. Ultrasensitive Magnetoelectric Sensing System for Pico-Tesla MagnetoMyoGraphy. IEEE Trans. Biomed. Circuits Syst. 2020;14:971–984. doi: 10.1109/TBCAS.2020.2998290. [DOI] [PubMed] [Google Scholar]
  • 6.Koch H. Recent Advances in Magnetocardiography. J. Electrocardiol. 2004;37:117–122. doi: 10.1016/j.jelectrocard.2004.08.035. [DOI] [PubMed] [Google Scholar]
  • 7.Fenici R., Brisinda D., Meloni A.M. Clinical Application of Magnetocardiography. Expert Rev. Mol. Diagn. 2005;5:291–313. doi: 10.1586/14737159.5.3.291. [DOI] [PubMed] [Google Scholar]
  • 8.Kwong J.S.W., Leithäuser B., Park J.-W., Yu C.-M. Diagnostic Value of Magnetocardiography in Coronary Artery Disease and Cardiac Arrhythmias: A Review of Clinical Data. Int. J. Cardiol. 2013;167:1835–1842. doi: 10.1016/j.ijcard.2012.12.056. [DOI] [PubMed] [Google Scholar]
  • 9.Duez L., Beniczky S., Tankisi H., Hansen P.O., Sidenius P., Sabers A., Fuglsang-Frederiksen A. Added Diagnostic Value of Magnetoencephalography (MEG) in Patients Suspected for Epilepsy, Where Previous, Extensive EEG Workup Was Unrevealing. Clin. Neurophysiol. 2016;127:3301–3305. doi: 10.1016/j.clinph.2016.08.006. [DOI] [PubMed] [Google Scholar]
  • 10.Fenici R., Brisinda D., Nenonen J., Fenici P. Phantom Validation of Multichannel Magnetocardiography Source Localization. Pacing and Clin. Electrophysiol. 2003;26:426–430. doi: 10.1046/j.1460-9592.2003.00063.x. [DOI] [PubMed] [Google Scholar]
  • 11.Bertero M., Piana M. Inverse problems in biomedical imaging: Modeling and methods of solution. In: Quarteroni A., Formaggia L., Veneziani A., editors. Complex Systems in Biomedicine. Springer; Milano, Italy: 2006. pp. 1–33. [Google Scholar]
  • 12.Yang J., Poh N. Recent Application in Biometrics. IntechOpen; London, UK: 2011. [Google Scholar]
  • 13.Murzin D., Mapps D.J., Levada K., Belyaev V., Omelyanchik A., Panina L., Rodionova V. Ultrasensitive Magnetic Field Sensors for Biomedical Applications. Sensors. 2020;20:1569. doi: 10.3390/s20061569. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Kleiner R., Koelle D., Ludwig F., Clarke J. Superconducting Quantum Interference Devices: State of the Art and Applications. Proc. IEEE. 2004;92:1534–1548. doi: 10.1109/JPROC.2004.833655. [DOI] [Google Scholar]
  • 15.Robbes D. Highly Sensitive Magnetometers—A Review. Sens. Actuators A Phys. 2006;129:86–93. doi: 10.1016/j.sna.2005.11.023. [DOI] [Google Scholar]
  • 16.Griffith W.C., Knappe S., Kitching J. Femtotesla Atomic Magnetometry in a Microfabricated Vapor Cell. Opt. Express. 2010;18:27167–27172. doi: 10.1364/OE.18.027167. [DOI] [PubMed] [Google Scholar]
  • 17.Johnson C.N., Schwindt P.D.D., Weisend M. Multi-Sensor Magnetoencephalography with Atomic Magnetometers. Phys. Med. Biol. 2013;58:6065–6077. doi: 10.1088/0031-9155/58/17/6065. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Osborne J., Orton J., Alem O., Shah V. Fully Integrated Standalone Zero Field Optically Pumped Magnetometer for Biomagnetism; Proceedings of the Steep Dispersion Engineering and Opto-Atomic Precision Metrology XI; San Francisco, CA, USA. 29 January–1 February 2018; pp. 89–95. [Google Scholar]
  • 19.Mhaskar R.R., Knappe S., Kitching J. Low-Frequency Characterization of MEMS-Based Portable Atomic Magnetometer; Proceedings of the 2010 IEEE International Frequency Control Symposium; Newport Beach, CA, USA. 1–4 June 2010; pp. 376–379. [Google Scholar]
  • 20.Oelsner G., IJsselsteijn R., Scholtes T., Krüger A., Schultze V., Seyffert G., Werner G., Jäger M., Chwala A., Stolz R. Integrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field. arXiv. 20212008.01570 [Google Scholar]
  • 21.Reermann J., Durdaut P., Salzer S., Demming T., Piorra A., Quandt E., Frey N., Höft M., Schmidt G. Evaluation of Magnetoelectric Sensor Systems for Cardiological Applications. Measurement. 2018;116:230–238. doi: 10.1016/j.measurement.2017.09.047. [DOI] [Google Scholar]
  • 22.Yarar E., Salzer S., Hrkac V., Piorra A., Höft M., Knöchel R., Kienle L., Quandt E. Inverse Bilayer Magnetoelectric Thin Film Sensor. Appl. Phys. Lett. 2016;109:022901. doi: 10.1063/1.4958728. [DOI] [Google Scholar]
  • 23.Tu C., Chu Z.-Q., Spetzler B., Hayes P., Dong C.-Z., Liang X.-F., Chen H.-H., He Y.-F., Wei Y.-Y., Lisenkov I., et al. Mechanical-Resonance-Enhanced Thin-Film Magnetoelectric Heterostructures for Magnetometers, Mechanical Antennas, Tunable RF Inductors, and Filters. Materials. 2019;12:2259. doi: 10.3390/ma12142259. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Lee E.W. Magnetostriction and Magnetomechanical Effects. Rep. Prog. Phys. 1955;18:184–229. doi: 10.1088/0034-4885/18/1/305. [DOI] [Google Scholar]
  • 25.Spetzler B., Golubeva E.V., Müller C., McCord J., Faupel F. Frequency Dependency of the Delta-E Effect and the Sensitivity of Delta-E Effect Magnetic Field Sensors. Sensors. 2019;19:4769. doi: 10.3390/s19214769. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Spetzler B., Golubeva E.V., Friedrich R.-M., Zabel S., Kirchhof C., Meyners D., McCord J., Faupel F. Magnetoelastic Coupling and Delta-E Effect in Magnetoelectric Torsion Mode Resonators. Sensors. 2021;21:2022. doi: 10.3390/s21062022. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Reermann J., Zabel S., Kirchhof C., Quandt E., Faupel F., Schmidt G. Adaptive Readout Schemes for Thin-Film Magnetoelectric Sensors Based on the Delta-E Effect. IEEE Sens. J. 2016;16:4891–4900. doi: 10.1109/JSEN.2016.2553962. [DOI] [Google Scholar]
  • 28.Osiander R., Ecelberger S.A., Givens R.B., Wickenden D.K., Murphy J.C., Kistenmacher T.J. A Microelectromechanical-based Magnetostrictive Magnetometer. Appl. Phys. Lett. 1996;69:2930–2931. doi: 10.1063/1.117327. [DOI] [Google Scholar]
  • 29.Gojdka B., Jahns R., Meurisch K., Greve H., Adelung R., Quandt E., Knöchel R., Faupel F. Fully Integrable Magnetic Field Sensor Based on Delta-E Effect. Appl. Phys. Lett. 2011;99:223502. doi: 10.1063/1.3664135. [DOI] [Google Scholar]
  • 30.Jahns R., Zabel S., Marauska S., Gojdka B., Wagner B., Knöchel R., Adelung R., Faupel F. Microelectromechanical Magnetic Field Sensor Based on ΔE Effect. Appl. Phys. Lett. 2014;105:052414. doi: 10.1063/1.4891540. [DOI] [Google Scholar]
  • 31.Zabel S., Kirchhof C., Yarar E., Meyners D., Quandt E., Faupel F. Phase Modulated Magnetoelectric Delta-E Effect Sensor for Sub-Nano Tesla Magnetic Fields. Appl. Phys. Lett. 2015;107:152402. doi: 10.1063/1.4932575. [DOI] [Google Scholar]
  • 32.Zabel S., Reermann J., Fichtner S., Kirchhof C., Quandt E., Wagner B., Schmidt G., Faupel F. Multimode Delta-E Effect Magnetic Field Sensors with Adapted Electrodes. Appl. Phys. Lett. 2016;108:222401. doi: 10.1063/1.4952735. [DOI] [Google Scholar]
  • 33.Spetzler B., Su J., Friedrich R.-M., Niekiel F., Fichtner S., Lofink F., Faupel F. Influence of the Piezoelectric Material on the Signal and Noise of Magnetoelectric Magnetic Field Sensors Based on the Delta-E Effect. APL Mater. 2021;9:031108. doi: 10.1063/5.0042448. [DOI] [Google Scholar]
  • 34.Spetzler B., Bald C., Durdaut P., Reermann J., Kirchhof C., Teplyuk A., Meyners D., Quandt E., Höft M., Schmidt G., et al. Exchange Biased Delta-E Effect Enables the Detection of Low Frequency PT Magnetic Fields with Simultaneous Localization. Sci. Rep. 2021;11:5269. doi: 10.1038/s41598-021-84415-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Nan T., Hui Y., Rinaldi M., Sun N.X. Self-Biased 215 MHz Magnetoelectric NEMS Resonator for Ultra-Sensitive DC Magnetic Field Detection. Sci. Rep. 2013;3:1985. doi: 10.1038/srep01985. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Li M., Matyushov A., Dong C., Chen H., Lin H., Nan T., Qian Z., Rinaldi M., Lin Y., Sun N.X. Ultra-Sensitive NEMS Magnetoelectric Sensor for Picotesla DC Magnetic Field Detection. Appl. Phys. Lett. 2017;110:143510. doi: 10.1063/1.4979694. [DOI] [Google Scholar]
  • 37.Staruch M., Matis B.R., Baldwin J.W., Bennett S.P., van’t Erve O., Lofland S., Bussmann K., Finkel P. Large Non-Saturating Shift of the Torsional Resonance in a Doubly Clamped Magnetoelastic Resonator. Appl. Phys. Lett. 2020;116:232407. doi: 10.1063/5.0010975. [DOI] [Google Scholar]
  • 38.Zhuang X., Sing M.L.C., Dolabdjian C., Wang Y., Finkel P., Li J., Viehland D. Sensitivity and Noise Evaluation of a Bonded Magneto(Elasto) Electric Laminated Sensor Based on In-Plane Magnetocapacitance Effect for Quasi-Static Magnetic Field Sensing. IEEE Trans. Magn. 2015;51:1–4. doi: 10.1109/TMAG.2014.2356852. [DOI] [Google Scholar]
  • 39.Staruch M., Yang M.-T., Li J.F., Dolabdjian C., Viehland D., Finkel P. Frequency Reconfigurable Phase Modulated Magnetoelectric Sensors Using ΔE Effect. Appl. Phys. Lett. 2017;111:032905. doi: 10.1063/1.4994663. [DOI] [Google Scholar]
  • 40.Stutzke N.A., Russek S.E., Pappas D.P., Tondra M. Low-Frequency Noise Measurements on Commercial Magnetoresistive Magnetic Field Sensors. J. Appl. Phys. 2005;97:10Q107. doi: 10.1063/1.1861375. [DOI] [Google Scholar]
  • 41.Deak J.G., Zhou Z., Shen W. Tunneling Magnetoresistance Sensor with PT Level 1/f Magnetic Noise. AIP Adv. 2017;7:056676. doi: 10.1063/1.4978465. [DOI] [Google Scholar]
  • 42.Lukat N., Friedrich R.-M., Spetzler B., Kirchhof C., Arndt C., Thormählen L., Faupel F., Selhuber-Unkel C. Mapping of Magnetic Nanoparticles and Cells Using Thin Film Magnetoelectric Sensors Based on the Delta-E Effect. Sens. Actuators A Phys. 2020;309:112023. doi: 10.1016/j.sna.2020.112023. [DOI] [Google Scholar]
  • 43.Chu Z., Shi W., Shi H., Chen Q., Wang L., PourhosseiniAsl M.J., Xiao C., Xie T., Dong S. A 1D Magnetoelectric Sensor Array for Magnetic Sketching. Adv. Mater. Technol. 2019;4:1800484. doi: 10.1002/admt.201800484. [DOI] [Google Scholar]
  • 44.Cuong T.D., Viet Hung N., Le Ha V., Tuan P.A., Duong D.D., Tam H.A., Duc N.H., Giang D.T.H. Giant Magnetoelectric Effects in Serial-Parallel Connected Metglas/PZT Arrays with Magnetostrictively Homogeneous Laminates. J. Sci. Adv. Mater. Devices. 2020;5:354–360. doi: 10.1016/j.jsamd.2020.06.005. [DOI] [Google Scholar]
  • 45.Xi H., Lu M.-C., Yang Q.X., Zhang Q.M. Room Temperature Magnetoelectric Sensor Arrays For Application of Detecting Iron Profiles in Organs. Sens. Actuators A Phys. 2020;311:112064. doi: 10.1016/j.sna.2020.112064. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Lu Y., Cheng Z., Chen J., Li W., Zhang S. High Sensitivity Face Shear Magneto-Electric Composite Array for Weak Magnetic Field Sensing. J. Appl. Phys. 2020;128:064102. doi: 10.1063/5.0011931. [DOI] [Google Scholar]
  • 47.Li H., Zou Z., Yang Y., Shi P., Wu X., Ou-Yang J., Yang X., Zhang Y., Zhu B., Chen S. Microbridge-Structured Magnetoelectric Sensor Array Based on PZT/FeCoSiB Thin Films. IEEE Trans. Magn. 2020;56:1–4. doi: 10.1109/TMAG.2020.2976877. [DOI] [Google Scholar]
  • 48.Kim H.J., Wang S., Xu C., Laughlin D., Zhu J., Piazza G. Piezoelectric/Magnetostrictive MEMS Resonant Sensor Array for in-Plane Multi-Axis Magnetic Field Detection; Proceedings of the 2017 IEEE 30th International Conference on Micro Electro Mechanical Systems (MEMS); Las Vegas, NV, USA. 22–26 January 2017; pp. 109–112. [Google Scholar]
  • 49.Lage E., Kirchhof C., Hrkac V., Kienle L., Jahns R., Knöchel R., Quandt E., Meyners D. Exchange Biasing of Magnetoelectric Composites. Nat. Mater. 2012;11:523–529. doi: 10.1038/nmat3306. [DOI] [PubMed] [Google Scholar]
  • 50.Yarar E., Hrkac V., Zamponi C., Piorra A., Kienle L., Quandt E. Low Temperature Aluminum Nitride Thin Films for Sensory Applications. AIP Adv. 2016;6:075115. doi: 10.1063/1.4959895. [DOI] [Google Scholar]
  • 51.Durdaut P., Penner V., Kirchhof C., Quandt E., Knöchel R., Höft M. Noise of a JFET Charge Amplifier for Piezoelectric Sensors. IEEE Sens. J. 2017;17:7364–7371. doi: 10.1109/JSEN.2017.2759000. [DOI] [Google Scholar]
  • 52.Jahns R., Knöchel R., Greve H., Woltermann E., Lage E., Quandt E. Magnetoelectric Sensors for Biomagnetic Measurements; Proceedings of the 2011 IEEE International Symposium on Medical Measurements and Applications; Bari, Italy. 30–31 May 2011; pp. 107–110. [Google Scholar]
  • 53.Durdaut P., Reermann J., Zabel S., Kirchhof C., Quandt E., Faupel F., Schmidt G., Knöchel R., Höft M. Modeling and Analysis of Noise Sources for Thin-Film Magnetoelectric Sensors Based on the Delta-E Effect. IEEE Trans. Instrum. Meas. 2017;66:2771–2779. doi: 10.1109/TIM.2017.2709478. [DOI] [Google Scholar]
  • 54.Durdaut P., Rubiola E., Friedt J.-M., Müller C., Spetzler B., Kirchhof C., Meyners D., Quandt E., Faupel F., McCord J., et al. Fundamental Noise Limits and Sensitivity of Piezoelectrically Driven Magnetoelastic Cantilevers. J. Microelectromech. Syst. 2020;29:1347–1361. doi: 10.1109/JMEMS.2020.3014402. [DOI] [Google Scholar]
  • 55.Spetzler B., Kirchhof C., Reermann J., Durdaut P., Höft M., Schmidt G., Quandt E., Faupel F. Influence of the Quality Factor on the Signal to Noise Ratio of Magnetoelectric Sensors Based on the Delta-E Effect. Appl. Phys. Lett. 2019;114:183504. doi: 10.1063/1.5096001. [DOI] [Google Scholar]
  • 56.Durdaut P. Ph.D. Thesis. Kiel University; Kiel, Germany: 2019. Ausleseverfahren Und Rauschmodellierung Für Magnetoelektrische Und Magnetoelastische Sensorsysteme. [Google Scholar]
  • 57.Spetzler B., Kirchhof C., Quandt E., McCord J., Faupel F. Magnetic Sensitivity of Bending-Mode Delta-E-Effect Sensors. Phys. Rev. Appl. 2019;12:064036. doi: 10.1103/PhysRevApplied.12.064036. [DOI] [Google Scholar]
  • 58.Wang Y.J., Gao J.Q., Li M.H., Shen Y., Hasanyan D., Li J.F., Viehland D. A Review on Equivalent Magnetic Noise of Magnetoelectric Laminate Sensors. Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 2014;372:20120455. doi: 10.1098/rsta.2012.0455. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 59.Ding L., Saez S., Dolabdjian C., Melo L.G.C., Yelon A., Menard D. Equivalent Magnetic Noise Limit of Low-Cost GMI Magnetometer. IEEE Sens. J. 2009;9:159–168. doi: 10.1109/JSEN.2008.2011067. [DOI] [Google Scholar]
  • 60.Matyushov A.D., Spetzler B., Zaeimbashi M., Zhou J., Qian Z., Golubeva E.V., Tu C., Guo Y., Chen B.F., Wang D., et al. Curvature and Stress Effects on the Performance of Contour-Mode Resonant ΔE Effect Magnetometers. Adv. Mater. Technol. 2021;6:2100294. doi: 10.1002/admt.202100294. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 61.Oppenheim A.V., Schafer R.W., Buck J.R. Discrete-Time Signal Processing. 2nd ed. Prentice Hall; Upper Saddle River, NJ, USA: 1998. [Google Scholar]
  • 62.Orfanidis S.J. Introduction to Signal Processing. Prentice Hall; Hoboken, NJ, USA: 1996. [Google Scholar]
  • 63.Welch P.D. The Use of Fast Fourier Transform for the Estimation of Power Spectra: A Method Based on Time Averaging Over a Short, Modified Periodograms. IEEE Trans. Audio Electroacoust. 1967;15:70–73. doi: 10.1109/TAU.1967.1161901. [DOI] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data presented in this study are available on reasonable request from the corresponding author.