Configuration G (W/m2) T (°C) Voc (V) Isc (A) Vmp (V) Imp (A) Pmax (W)
Single module 195 11.46 42.23 0.84 37.38 0.74 27.07
401 19.70 42.49 1.91 35.50 1.79 63.72
603 26.06 42.39 3.12 34.75 2.83 98.41
871 41.39 41.01 5.17 29.08 4.78 139.03
1019 45.1 40.93 6.20 29.20 5.68 165.89
Two modules in series 198.34 6.44 85.49 0.86 77.55 0.74 57.23
396.59 14.71 85.71 1.92 74.87 1.74 130.66
608.45 28.75 83.91 3.46 69.44 3.10 215.27
799.63 39.05 82.57 5.07 64.50 4.42 283.80
1001.68 50.96 80.07 7.05 58.02 6.45 374.11
Whole PV generator 190.18 11.46 80.65 2.63 67.69 2.46 166.59
389.94 19.70 84.17 6.18 69.57 5.82 404.89
603.68 26.06 82.89 9.35 66.74 8.96 597.85
776.29 41.39 81.84 12.45 64.06 11.83 757.94
878.30 45.1 80.82 13.81 62.12 13.16 820.19