Table 4.
Irradiance, temperature, and electrical parameters measured during characterization for different configurations of the PV modules.
| Configuration | G (W/m2) | T (°C) | Voc (V) | Isc (A) | Vmp (V) | Imp (A) | Pmax (W) |
|---|---|---|---|---|---|---|---|
| Single module | 195 | 11.46 | 42.23 | 0.84 | 37.38 | 0.74 | 27.07 |
| 401 | 19.70 | 42.49 | 1.91 | 35.50 | 1.79 | 63.72 | |
| 603 | 26.06 | 42.39 | 3.12 | 34.75 | 2.83 | 98.41 | |
| 871 | 41.39 | 41.01 | 5.17 | 29.08 | 4.78 | 139.03 | |
| 1019 | 45.1 | 40.93 | 6.20 | 29.20 | 5.68 | 165.89 | |
| Two modules in series | 198.34 | 6.44 | 85.49 | 0.86 | 77.55 | 0.74 | 57.23 |
| 396.59 | 14.71 | 85.71 | 1.92 | 74.87 | 1.74 | 130.66 | |
| 608.45 | 28.75 | 83.91 | 3.46 | 69.44 | 3.10 | 215.27 | |
| 799.63 | 39.05 | 82.57 | 5.07 | 64.50 | 4.42 | 283.80 | |
| 1001.68 | 50.96 | 80.07 | 7.05 | 58.02 | 6.45 | 374.11 | |
| Whole PV generator | 190.18 | 11.46 | 80.65 | 2.63 | 67.69 | 2.46 | 166.59 |
| 389.94 | 19.70 | 84.17 | 6.18 | 69.57 | 5.82 | 404.89 | |
| 603.68 | 26.06 | 82.89 | 9.35 | 66.74 | 8.96 | 597.85 | |
| 776.29 | 41.39 | 81.84 | 12.45 | 64.06 | 11.83 | 757.94 | |
| 878.30 | 45.1 | 80.82 | 13.81 | 62.12 | 13.16 | 820.19 |