Table 4.
Name. | Description | ||
---|---|---|---|
Hot Rolling | Cold Rolling | Final Annealing | |
Q-25-1000 | 1 mm, water quenching | 0.25 mm | 1000 °C, 1 min |
F-25-900 | 1 mm, furnace cooling | 0.25 mm | 900 °C, 2 min |
F-25-1000 | 1 mm, furnace cooling | 0.25 mm | 1000 °C, 1 min |
F-25-1100 | 1 mm, furnace cooling | 0.25 mm | 1100 °C, 1 min |
F-50-1000 | 1 mm, furnace cooling | 0.50 mm | 1000 °C, 1 min |