Abstract
Introduction: This study aimed to show the clinical outcomes of implants inserted by guided surgery supporting mandibular overdentures in edentulous patients. Patients and methods: Mandibular edentulous patients were diagnosed with an oral examination, cone-beam computerized tomography, and diagnostic casts for intermaxillary relations and treated with overdentures over two implants by guided surgery. After flapless surgery, implants were early loaded with an overdenture at 6 weeks. Results and discussion: Fourteen patients (nine females and five males) were treated with 28 implants. Four patients (28.6%) had a previous history of periodontitis. Five patients (35.7%) were smokers. Nine patients (64.3%) suffered from systemic diseases (i.e., diabetes, cardiovascular diseases). The clinical follow-up of the study was 44.7 ± 31.4 months. Clinical outcomes showed a global success of 100% of implants. Fourteen overdentures were placed in the patients over the implants. Mean marginal bone loss was 1.25 mm ± 0.95 mm. Four patients (28.6%) showed some kind of mechanical prosthodontic complications. Six implants (21.4%) were associated with peri-implantitis. Conclusions: This study indicates that treatment of mandibular edentulous patients with overdentures by guided surgery and early loading of implants placed appears to be a successful implant protocol.
Keywords: guided implant surgery, overdenture, early loading, edentulous mandible
1. Introduction
The prosthodontic rehabilitation of edentulous patients by implant-supported restorations is considered a predictable and successful modality of dental treatment [1,2]. The implant-supported overdenture has become the therapy of choice for the edentulous mandible in geriatric patients [3]. Implant-supported overdentures have been proven to be an effective treatment alternative for restoring fully edentulous patients with a high success rate [4]. Moreover, implant-supported mandibular overdentures provide patients with a significant improvement of oral quality of life compared with conventional removable dentures [5].
Guided implant dentistry has rapidly grown in popularity, and is now widely used as a real alternative to planning for surgical and prosthodontic steps of implant treatment [6,7]. During the last decades, the incorporation of three-dimensional imaging technology by the introduction of cone-beam computed tomography (CBCT) allowed the acquisition of the bone volume and density of the jaws in a simple protocol and with a considerable reduction of radiation absorbed by the patient [8,9].
The development of specific software in clinical guided implant dentistry provides a virtual method to treatment planning of flapless implant surgery in rehabilitation of totally and partially edentulous patients [10,11]. The accuracy of positioning of the implants in alveolar ridges must be considered an important factor in clinical situations with limited bone volume. In geriatric edentulous patients, the loss of mandibular teeth induces many anatomical changes, particularly regarding its shape, volume, and density. The diagnosis of these bone characteristics by CBCT allows a clinician to select the best implant surgery to achieve good primary stability and fast osseointegration [12,13].
Several studies have reported excellent clinical outcomes of guided implant treatment in fully edentulous patients, demonstrating that this comprehensive approach has a good implant survival and that implant-supported fixed prosthesis can be delivered to the patient [14,15]. The use of CBCT to plan the insertion of implants by surgical guides, aided by specific software, includes the use of a flapless technique with an important reduction of surgery times, postoperative pain, and better patient comfort [16,17].
However, only a few clinical studies have evaluated the efficacy of guided implant dentistry in the treatment of edentulous patients with overdentures [18,19]. There are only several case reports available to document the feasibility of this technique for overdentures [20,21,22,23,24]. This technique of guided flapless implant surgery has been suggested for the geriatric edentulous mandibular patients because CBCT allows that certain anatomical structures (mental foramina, inferior alveolar nerve) are easily identified and protected [12,13,18,21]. The prosthetic approach with overdenture induces the choice of implant position whose characteristics (shape, surface, thread) are consistent with the underlying bone diagnosis (volume and cortical density and trabecular spaces) [20,22]. Additionally, guided implant dentistry minimizes the possibility of postoperative soft tissue loss and reduces the surgery duration compared to patients with conventional flaps [23].
This study aimed to investigate the clinical results of guided surgery of implants and early loading with mandibular overdentures in the treatment of edentulous patients.
2. Materials and Methods
This study was carried out at the Faculty of Dentistry of the University of Seville during the years 2013 to 2019. Due to the nature of clinical research, the principles described in the Declaration of Helsinki were taken into account for the design of the study. The approval of the ethics committee of the University of Seville and the informed consent of the patients were also obtained.
The inclusion criteria were edentulous lower jaw patients in need of rehabilitation with mandibular overdentures implant-supported. The study population consisted of 9 women and 5 men, aged between 53 and 85 years, resulting in a total of 14 patients with a mean age of 70.6. The exclusion criteria were the following: (a) presence of chronic systemic disease, such as uncontrolled diabetes mellitus or coagulation disorders; (b) harmful habits such as smoking with consumption greater than 10 cigarettes/day, alcoholism, or drug use; (c) oral conditions such as uncontrolled periodontal disease and bruxism; previous history of periodontitis but in a situation of controlled disease are not excluded. Regarding treatment planning, additionally to the intraoral examination and clinical photographs, CBCT and diagnostic models for intermaxillary relationships were performed. Possible implant treatment options were explained to the patients, choosing the implant-supported overdenture through guided surgery.
The patients were prescribed an antibiotic treatment consisting of 500 mg of amoxicillin and 125 mg of clavulanic acid 1 h before the intervention, as well as every 8 h/7 days after the treatment. As analgesic regimen, ibuprofen 600 mg/6 h/7 days was indicated. For the following 30 days, a chlorhexidine mouthwash was prescribed, 2 times per day. Articaine with adrenaline as a vasoconstrictor was injected as local anesthesia for implant treatment.
All participants underwent cone-beam computer tomography (Picasso Master 3D®, Vatech, Gyeonggi-do, Korea) with a scan prosthesis and occlusal index positioned in the mouth. The implants were planned in 3D software (Galimplant 3D ®, Galimplant, Sarria, Spain) in the optimal position considering both the alveolar process and the prosthetic demands (Figure 1 and Figure 2).
A flapless surgical approach was chosen with the help of a guided surgical template. The design of this surgical template was performed using digital planning (Figure 3). In all patients, the template was secured to the underlying bone with two screws in the vestibular plates to avoid movement during the surgery. Guided surgery began with the preparation of two surgical beds, through the sequential steps of drills according to a protocol of progressive diameter increase. Finally, the implants were inserted positioned by the guide.
The implants selected for insertion in the patients were Surgimplant ® (Galimplant, Sarria, Spain), which were characterized by an internal connection and a surface treatment consisting of sandblasting and acid etching. Insertion torque and resonance frequency were analyzed to determine implant stability after placement. Insertion torque was measured before the removal of the surgical guide. An insertion torque ≥35 Ncm was considered adequate for implant stability at the time of placement. [8,14]. Finally, resonance frequency analysis was used to confirm the stability of each implant immediately after removal of the guide once the implants have been placed. Adequate primary stability required an ISQ (Implant Stability Quotient) value between 55 and 85 [15]. However, an ISQ value greater than 65 was considered to perform a one-stage surgery and an early loading protocol (Table 1) [25]. After the surgical procedure, healing abutments were connected to the implants. Sutures were not used in any patient.
Table 1.
ISQ Value | Clinical Recommendation | |
---|---|---|
Primary stability inadequate | <55 | Increase implant stability |
Low stability | 55–60 | 2-stage surgery/ Conventional loading |
Medium stability | 60–69 | Possible 1-stage surgery/ Early loading |
High stability | >70 | Immediate loading |
Existing dentures were molded and relined with soft material to not interfere with the peri-implant tissues and reduce occlusal forces on the implants. After six weeks of surgery, early loading was performed. An open impression technique with individualized tray and addition silicone material was used. An Overdent ® (Galimplant, Sarria, Spain) attachment system was used in the manufactured and retention of the overdentures over the osseointegrated implants. (Figure 4 and Figure 5).
Implant stability and absence of peri-implant radiolucency, mucosal suppuration, and pain were considered as survival criteria. All patients were included in a maintenance program consisting of clinical and radiological examination and cleaning of prostheses and implants. The frequency of revisions was set at 3 and 6 months and annually after guided implant insertion. Periapical radiographs acquired digitally using positioners were used to measure follow-up in marginal bone loss. The analyzed variables included patient information (gender, age, dental health, systemic diseases, history of periodontitis, smoking habit), details about the placed implants (type, number, position, diameter, and length), and the implant-supported overdenture including the dates of delivery. In addition, surgical, biological, and technical complications that occurred during implant insertion, postoperatively, or during function in the follow-up period, were recorded.
A statistical analysis of the variables obtained was carried out using SPSS software (SPSS 11.5.0, SPSS, Chicago, IL, USA). Descriptive statistics were used to report the clinical results of the study. Absolute and relative percentage frequencies of qualitative variables were obtained, and chi-square test was used to analyze distributions. Means, standard deviations (SD), medians, ranges, and 95% confidence intervals (CI) were obtained for the quantitative variables. An analysis of variance (ANOVA) was used to confirm the similarities in the groups. The analysis of differences between the groups created based on the different risk factors measured was performed using the non-parametric Mann–Whitney U test. The level of statistical significance was established for a value of p < 0.05.
3. Results
Twenty-eight implants were inserted in 14 edentulous mandible patients, 9 females, and 5 males. No significant statistical differences were found related to sex and age (chi-square test, p = 0.87208). Four patients (28.6%) had a previous history of periodontitis. Five patients (35.7%) were smokers (Table 2). Nine patients (64.3%) exhibited medical conditions (i.e., diabetes, cardiovascular diseases).
Table 2.
n | % | |
---|---|---|
Females | 9 | 64.3 |
Males | 5 | 35.7 |
History of periodontitis | 4 | 28.6 |
Smokers | 5 | 35.7 |
Medical conditions | 9 | 64.3 |
n = patient.
The average follow-up period was 44.7 ± 31.4 months (ranged: 12–84 months). Twenty-eight implants (100%) had a diameter of 4 mm. Twenty implants (71.4%) were 10 mm in length, and 8 (28.6%) were 12 mm. No implant was lost during the follow-up (Table 3). The cumulative survival rate for all implants was 100%.
Table 3.
n | % | |
---|---|---|
4 mm implant diameter | 28 | 100 |
10 mm implant length | 20 | 71.4 |
12 mm implant length | 8 | 28.6 |
Loss of implant | 0 | 0 |
n = implant.
During the follow-up period, four implants (14.3%) in two patients (14.3%) were associated with peri-implantitis (Table 4). Peri-implantitis was more frequent in those patients with a previous history of periodontitis (50%) and smoking patients (40%).
Table 4.
n | % | |
---|---|---|
Implant loss | 0 | 0 |
Peri-implantitis | 2 | 14.3 |
Technical complications | 4 | 28.6 |
n = implant.
The mean marginal bone loss was 1.25 ± 0.94 mm, ranging from 0.8 to 1.7 mm during the follow-up evaluation (Table 5). In patients less than 70 years, the marginal bone loss was 0.91 ± 0.88 mm compared with 1.50 ± 0.80 for more than 70 years, with statistical differences (ANOVA; p = 0.0077) (Table 5).
Table 5.
Age * | ≤70 years | >70 years | |
0.91 ± 0.88 | 1.50 ± 0.80 | p = 0.0077 | |
Gender | Female | Male | |
1.21 ± 0.90 | 1.32 ± 1.04 | p = 0.6763 | |
History of periodontitis | + | - | |
1.40 ± 1.10 | 1.19 ± 0.88 | p = 0.4436 | |
Smokers | + | - | |
1.32 ± 1.04 | 1.21 ± 0.90 | p = 0.6763 | |
Medical conditions | + | 1.25 - |
|
1.38 ± 0.93 | 1.00 ± 0.86 | p = 0.1173 | |
Follow-up * | ≤5 years | >5 years | |
0.93 ± 0.81 | 1.66 ± 0.58 | p = 0.0001 | |
Total | 1.25 ± 0.94 (0.8–1.7) |
(*) Statistically significant.
In female patients, the marginal bone loss was 1.21 ± 0.90 compared with 1.32 ± 1.04 in male patients, without statistical differences (ANOVA; p = 0.6763) (Table 5).
In patients with a history of periodontitis, the marginal bone loss was 1.40 ± 1.10 compared with 1.19 ± 0.88 in patients without a history of periodontitis, without statistical differences (ANOVA; p = 0.4436) (Table 5).
In smoking patients, the marginal bone loss was 1.32 ± 1.04; while that in patients without smoking habits was 1.21 ± 0.90 mm. No significant statistical differences were found (ANOVA; p = 0.6763) (Table 5).
In patients with systemic diseases, the marginal bone loss was 1.38 ± 0.93; and 1.00 ± 0.86 for patients without medical conditions without statistical differences (ANOVA; p = 0.1173) (Table 5).
In patients with a follow-up less than 5 years, the marginal bone loss was 0.93 ± 0.81 compared with 1.66 ± 0.58 with a follow-up more than 5 years, with statistical differences (ANOVA; p = 0.0001) (Table 5).
After 6 weeks of healing period, 14 overdentures were performed over 28 implants placed in the patients. Mechanical prosthodontic complications were recorded in four patients (28.5%). (Table 4). Two patients (14.2%) showed resin fracture of a prosthesis, and two patients (14.2%) needed the change of locator-attachment system.
4. Discussion
The aim of this study was to evaluate clinical outcomes in planning and treatment by implant-guided surgery of edentulous patients with a mandibular overdenture. The rehabilitation of edentulous mandible patients constitutes an important challenge because optimal implant planning is strongly related to a correct diagnosis to achieve a successful prosthodontic rehabilitation [14,15].
The imaging diagnosis by CBCT allows the clinician to reduce the risk of damaging vital structures in mandibular areas with limited residual bone. The surgical placement of implants in the anterior edentulous mandible for overdenture treatment is a predictable option with long-term successful results. However, implant-guided surgery in the atrophic anterior mandible presents several anatomic challenges owing to the vascular and neurologic structures related to this region. The incorporation and development of CBCT have resulted in a better appreciation of the risks involved with surgery in this area [14,15].
Moreover, in the anatomical diagnosis of the edentulous mandible, the assessment of the bone volume and density of the mandible by CBCT allows a practitioner to select the best implant design and surface to achieve good primary stability and speed osseointegration. All patients of the present study were evaluated, by CBCT, before the surgery to assess the specific bone characteristics, as cortical density and trabecular spaces, choosing the best location for the placement of implants, also according to prosthodontic approach with overdentures [12].
In the present study, based on the clinical and CBCT findings and the patient’s expectations, treatment planning was established to place two implants in the anterior mandible by using flapless surgery. Fourteen patients received 28 implants, inserted through a flapless guided surgery. No implants were lost, during the mean clinical follow-up of 44.7 ± 31.4 months. The cumulative implant survival rate was 100%. Flapless implant surgery is a minimally invasive surgical approach that has several important advantages for both the clinician and the patient [14,15]. Flapless guided implant surgery increases the ability to insert implants more precisely, specifically in fully edentulous cases, with an important reduction of surgery duration, better clinical conditions after surgery, and the possibility of placing restorations for immediate loading. Computer-guided dental implant systems also provide necessary information for the prosthetic evaluation of mandibular edentulous patients [18,19,20,21,22,23,24].
Evidence provided by implant-supported mandibular overdenture research on different loading protocols is important. Several systematic reviews have been published about the clinical applicability of conventional-, early-, and immediate-loaded implants for overdenture treatment. Among the studies, the mandibular overdenture design included the use of two, three, and four implants and different attachment systems as locator, bar, and balls [26,27,28].
The mean MBL found by us (1.25 mm) is higher than that reported by Galindo et al. in 2015 [29], who published a 0.6 mm loss (mean distal and mesial) at 6 months; and 1.11 mm at 18 months (mean distal and mesial). Our study has a mean follow-up of 44.7 months (±31.4), and if we analyze other studies, such as the one by Palacios-Garzón et al. [30], they accept a loss of less than 2 mm in the first year. However, we must not forget that losses greater than 0.5 mm in the first year increase the risk of presenting peri-implantitis in the long term by 5.43 times [31]. Both in the cases of peri-implantitis, and with regard to the MBL data, we have not been able to relate them to the height of the locator-attachment system used, all of which is that the literature refers to a higher bone order in the lower systems [32,33].
Computer-guided surgery in the rehabilitation with overdentures, by immediate loading of four implants, of edentulous mandibular patients has been investigated in several studies [18,19,24,28]. During a follow-up of 2 years, 10 consecutive patients were restored with implant-supported overdentures [18]. Patients were treated with four intraforaminal implants using a computer-guided flapless approach. No implant was lost. Patients demonstrate the ability of oral hygiene for maintenance of peri-implant tissue health. The satisfaction of patients was very high. These results reported that computer-assisted implant dentistry can be a predictable protocol for treating elderly edentulous patients with a mandibular overdenture [18]. These satisfying results were confirmed by a recent one-year randomized controlled clinical trial [19]. Thirty mandibular edentulous patients were rehabilitated using overdentures supported by four implants, inserted by guided surgery in canine and second premolar position. These patients were randomly distributed into two groups, performing an immediate loading protocol using resilient stud (locator) or stress-free implant bar (SFI-Bar) attachments. After a one-year follow-up, implant survival in the locator group was 96.6%, while in the group using SFI-Bars, it was 98.3%. The locator showed significantly higher overall satisfaction, satisfaction with retention, comfort, and cleanliness of overdentures compared to bar-overdenture-rehabilitated patients. [19].
Immediate loading of two implants in overdentures by guided surgery, in edentulous mandibular patients, has been investigated in some clinical cases [22,23]. In these clinical situations was necessary high primary implant stability measured by resonance frequency analysis. Implant stability quotient values over 65, which was a prerequisite for the immediate loading, should be accomplished. Locator abutments were inserted on the implants and the metal housings were seated on the locators [23]. Another type of used retention system of overdentures was magnetic attachments [22].
In the present study, after guided placement of implants, the treatment planning was the early delivery of implant-retained overdentures at 6 weeks. No implants were lost, during the clinical follow-up. The cumulative implant survival rate was 100%. Early loading of two implants placed in edentulous mandibular patients can be a reliable and predictable technique for implant-supported overdentures [26,27]. Although all three loading protocols (conventional, early, immediate) provide high survival rates of treatment with overdentures, early- and conventional-loading protocols are still better documented than immediate loading and seem to result in fewer implant failures during the first year of clinical follow-up [26].
Marginal bone loss in overdentures by guided surgery implants has been reported in a recent study [19]. The marginal bone loss of immediately loaded implants ranged from 0.68 to 0.83 mm after a 1-year clinical follow-up. Similar mean values were obtained in locator (0.83 ± 0.10 mm) and bar retention systems (0.87 ± 0.13 mm). Marginal bone loss was significantly higher at 12 months compared with 6 months. This increased marginal bone loss can be due to the bone response to overdenture loading and bone maturation combined with functional occlusal forces [19]. In the present study, the mean marginal bone loss was 1.25 ± 0.94 mm during a follow-up period of 44.7 ± 31.4 months. Clinical outcomes showed a higher significant marginal bone loss in patients for more than 70 years and followed more than 5 years. Additionally, a common history of medical conditions (64.3%), smoking (35.7%), and periodontitis background (28.6%) can explain the higher mean values of marginal bone loss in the patients of the present study.
The global satisfaction of patients with computer-guided surgery and prosthetic rehabilitation with overdentures is very high because the postoperative pain and discomfort is very low and improves the compliance in the functional and aesthetic outcomes of prosthodontic treatment [5,18,24]. However, biological and technical complications had also been reported in several studies of treatment with implants placed using computer-guided surgery [28,34]. In the present study, four implants (14.3%) in two patients (14.3%) were associated with peri-implantitis. Peri-implantitis was more frequent in those patients with a previous history of periodontitis (50%) and smoking patients (40%). Additionally, the locators abutments can show an important vertical bone loss with higher plaque and gingival scores and increased probing depth with the progress of time that can explain the development of peri-implantitis in susceptible patients (i.e., periodontitis background and smoking habits) [19].
Prosthodontic complications were frequent in the present study. Four patients (28.5%) showed some kind of technical complications. Two patients (14.2%) showed resin fracture of the prosthesis, and two patients (14.2%) needed the change of locator-attachment system. The matrix resiliency among different locator systems can eventually be compromised by insertion and removal of the overdenture. This prosthetic complication may require reactivation or even replacement of the matrix; however, this maintenance procedure can be easily provided by the clinician in clinical practice [27].
5. Conclusions
Guided implant dentistry is widely used as a comprehensive alternative to planning for surgical and prosthodontic steps of treatment of edentulous patients. This study indicates that the treatment of edentulous patients with mandibular overdentures by guided surgery and early loading of implants placed appears to be a successful implant protocol.
Acknowledgments
The authors kindly acknowledge the collaboration of Galimplant S.L. (Sarria, Spain) for the support given to the technology and materials used for the treatment of patients.
Author Contributions
Conceptualization, E.V.-O. and J.L.-L.; methodology, N.M.G. and I.O.-G.; software, J.M.-M. and E.N.-M.; formal analysis, J.L.R.-R. and D.C.-B.; investigation, N.M.G. and E.V.-O.; resources, J.M.-M. and E.N.-M.; data curation, A.J.-G. and L.M.-G.; writing—original draft preparation, A.J.-G. and L.M.-G.; writing—review and editing, E.V.-O. and I.O.-G.; visualization, J.L.R.-R. and D.C.-B.; supervision, E.V.-O. and J.L.-L. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Ethics Committee of the University of Seville. The project has been approved by the Ethical Committee for Experimentation of the University of Seville (9-9-2011). According to the signature of its president.
Informed Consent Statement
Informed consent was obtained from all subjects involved in the study.
Data Availability Statement
The associated data of a statistical nature can be requested to: jl.lopez@ub.edu & evelasco@us.es.
Conflicts of Interest
The authors declare no conflicts of interest.
Footnotes
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
- 1.Attard N.J., Zarb G.A. Long-term treatment outcomes in edentulous patients with implant-fixed prostheses: The Toronto study. Int. J. Prosthodont. 2004;17:417–424. doi: 10.1016/j.prosdent.2004.09.017. [DOI] [PubMed] [Google Scholar]
- 2.Velasco-Ortega E., Jiménez-Guerra A., Monsalve-Guil L., Ortiz-García I., Nicolás-Silvente A.I., Segura-Egea J.J., López-López J. Long-term clinical outcomes of treatment with dental implants with acid etched surface. Materials. 2020;13:1553. doi: 10.3390/ma13071553. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Reissmann D.R., Dard M., Lamprecht R., Struppek J., Heydecke G. Oral health-related quality of life in subjects with implant-supported prostheses: A systematic review. J. Dent. 2017;65:22–40. doi: 10.1016/j.jdent.2017.08.003. [DOI] [PubMed] [Google Scholar]
- 4.Anas El-Wegoud M., Fayyad A., Kaddah A., Nabhan A. Bar versus ball attachments for implant-supported overdentures in complete edentulism: A systematic review. Clin. Implant Dent. Relat. Res. 2018;20:243–250. doi: 10.1111/cid.12551. [DOI] [PubMed] [Google Scholar]
- 5.Cardoso R.G., de Melo L.A., Barbosa G.A.S., Calderón P.D.S., Germano A.R., Mestriner W., Jr., Carreiro A.F.P. Impact of mandibular conventional denture and overdenture on quality of life and masticatory efficiency. Braz. Oral Res. 2016;30:102–110. doi: 10.1590/1807-3107BOR-2016.vol30.0102. [DOI] [PubMed] [Google Scholar]
- 6.Vercruyssen M., Laleman I., Jacobs R., Quirynen M. Computer-supported implant planning and guided surgery: A narrative review. Clin. Oral Implants Res. 2015;26:69–76. doi: 10.1111/clr.12638. [DOI] [PubMed] [Google Scholar]
- 7.Colombo M., Mangano C., Mijiritsky E., Krebs M., Hauschild U., Fortin T. Clinical applications and effectiveness of guided implant surgery: A critical review based on randomized controlled trials. BMC Oral Health. 2017;17:150. doi: 10.1186/s12903-017-0441-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Bornstein M.M., Horner K., Jacobs R. Use of cone beam computed tomography in implant dentistry: Current concepts, indications and limitations for clinical practice and research. Periodontol 2000. 2017;73:51–72. doi: 10.1111/prd.12161. [DOI] [PubMed] [Google Scholar]
- 9.Liu J., Chen H.Y., Dodo H., Yousef H., Firestone A.R., Chaudhry J., Johnston W.M., Lee D.J., Emam H.A., Kim D.G. Efficacy of cone-beam computed tomography in evaluating bone quality for optimum implant treatment planning. Implant Dent. 2017;26:405–411. doi: 10.1097/ID.0000000000000542. [DOI] [PubMed] [Google Scholar]
- 10.Hultin M., Svensson K.G., Trulsson M. Clinical advantages of computer-guided implant placement: A systematic review. Clin. Oral Implants Res. 2012;23:124–135. doi: 10.1111/j.1600-0501.2012.02545.x. [DOI] [PubMed] [Google Scholar]
- 11.D’Haese J., Ackhurst J., Wismeijer D., de Bruyn H., Tahmaseb A. Current state of the art of computer-guided implant surgery. Periodontol 2000. 2017;73:121–133. doi: 10.1111/prd.12175. [DOI] [PubMed] [Google Scholar]
- 12.Mense C., Saliba-Serre B., Ferrandez A.M., Hüe O., Ruquet M., Lalys L. Cone beam computed tomography analysis of the edentulous mandibular symphysis. J. Dent. Sci. 2021;16:115–122. doi: 10.1016/j.jds.2020.06.025. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Shelley A.M., Ferrero A., Brunton P., Goodwin M., Horner K. The impact of CBCT imaging when placing dental implants in the anterior edentulous mandible: A before–after study. Br. Dent. J. 2018;224:1–11. doi: 10.1259/dmfr.20140316. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Vieira D.M., Sotto-Maior B.S., Barros C.A., Reis E.S., Francischone C.E. Clinical accuracy of flapless computer-guided surgery for implant placement in edentulous arches. Int. J. Oral Maxillofac. Implants. 2013;28:1347–1351. doi: 10.11607/jomi.3156. [DOI] [PubMed] [Google Scholar]
- 15.Velasco-Ortega E., Jiménez-Guerra A., Ortiz-Garcia I., Moreno-Muñoz J., Núñez-Márquez E., Cabanillas-Balsera D., López-López J., Monsalve-Guil L. Immediate loading of implants placed by guided surgery in geriatric edentulous mandible patients. Int. J. Environ. Res. Public Health. 2021;18:4125. doi: 10.3390/ijerph18084125. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Marra R., Acocella A., Rispoli A., Sacco R., Ganz S.D., Blasi A. Full-mouth rehabilitation with immediate loading of implants inserted with computer-guided flapless surgery: A 3-year multicenter clinical evaluation with oral health impact profile. Impl. Dent. 2013;22:444–452. doi: 10.1097/ID.0b013e31829f1f7f. [DOI] [PubMed] [Google Scholar]
- 17.Komiyama A., Klinge B., Hultin M. Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery. Clin. Oral Implant Res. 2008;19:677–685. doi: 10.1111/j.1600-0501.2008.01538.x. [DOI] [PubMed] [Google Scholar]
- 18.Di Torresanto V.M., Milinkovic I., Torsello F., Cordaro L. Computer-assisted flapless implant surgery in edentulous elderly patients: A 2-year follow up. Quintessence Int. 2014;45:419–429. doi: 10.3290/j.qi.a31534. [DOI] [PubMed] [Google Scholar]
- 19.Elsyad M.A., Alsabri M.A., Elgamal M., Al-Tonbary G.Y. Resilient stud versus bar attachments for immediately loaded implants supporting mandibular overdentures: 1-year randomized controlled clinical trial. Int. J. Oral Maxillofac. Implants. 2021;36:346–354. doi: 10.11607/jomi.8472. [DOI] [PubMed] [Google Scholar]
- 20.Wada M., Andoh T., Gonda T., Maeda Y. Implant placement with a guided surgery system based on stress analyses utilizing the bone density: A clinical case report. J. Oral Impl. 2014;40:603–606. doi: 10.1563/AAID-JOI-D-12-00194. [DOI] [PubMed] [Google Scholar]
- 21.Bidra A.S. Flapless implant surgery to overcome anatomic challenges in the anterior mandible for overdenture therapy: A clinical report. J. Prosthet. Dent. 2014;111:175–180. doi: 10.1016/j.prosdent.2013.09.019. [DOI] [PubMed] [Google Scholar]
- 22.Sato D., Kanazawa M., Kim Y.K., Yokoyama S., Omura Y., Ozeki M., Minakuchi S., Kasugai S., Baba K. Immediate loading of two freestanding implants placed by computer-guided flapless surgery supporting a mandibular overdenture with magnetic attachments. J. Prosthodont. Res. 2016;60:54–62. doi: 10.1016/j.jpor.2015.09.002. [DOI] [PubMed] [Google Scholar]
- 23.Turkyilmaz I. Restoring edentulous mandible with an implant-retained overdenture in a day by means of flapless surgery and stereolithographic surgical guide: A case report. J. Oral Maxillofac. Res. 2019;10:5. doi: 10.5037/jomr.2019.10105. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Agusto M., Kordusky B., Bryington M.S., Salman A., Schincaglia G.P. Immediate loading of four guided unsplinted narrow implants supporting a maxillary overdenture: A minimally invasive approach. Clin. Adv. Periodontics. 2021 doi: 10.1002/cap.10147. [DOI] [PubMed] [Google Scholar]
- 25.Baltayan S., Pi-Anfruns J., Aghaloo T., Moy P.K. The predictive value of resonance frequency analysis measurements in the surgical placement and loading of endosseous implants. J. Oral Maxillofac. Surg. 2016;74:1145–1152. doi: 10.1016/j.joms.2016.01.048. [DOI] [PubMed] [Google Scholar]
- 26.Schimmel M., Srinivasan M., Herrmann F.R., Müller F. Loading protocols for implant-supported overdentures in the edentulous jaw: A systematic review and meta-analysis. Int. J. Oral Maxillofac. Implants. 2014;29:271–286. doi: 10.11607/jomi.2014suppl.g4.4. [DOI] [PubMed] [Google Scholar]
- 27.Borges G.A., Costa R.C., Nagay B.E., Magno M.B., Maia L.C., Barão V.A.R., Mesquita M.F. Long-term outcomes of different loading protocols for implant-supported mandibular overdentures: A systematic review and meta-analysis. J. Prosthet. Dent. 2021;125:732–745. doi: 10.1016/j.prosdent.2020.04.017. [DOI] [PubMed] [Google Scholar]
- 28.Wittwer G., Adeyemo W.L., Wagner A., Enislidis G. Computer-guided flapless placement and immediate loading of four conical screw-type implants in the edentulous mandible. Clin. Oral Impl. Res. 2007;18:534–539. doi: 10.1111/j.1600-0501.2007.01370.x. [DOI] [PubMed] [Google Scholar]
- 29.Galindo-Moreno P., León-Cano A., Ortega-Oller I., Monje A., O’ Valle F., Catena A. Marginal bone loss as success criterion in implant dentistry: Beyond 2 mm. Clin. Oral Implants Res. 2015;26:e28–e34. doi: 10.1111/clr.12324. [DOI] [PubMed] [Google Scholar]
- 30.Palacios-Garzón N., Mauri-Obradors E., Roselló-LLabrés X., Estrugo-Devesa A., Jané-Salas E., López-López J. Comparison of marginal bone loss between implants with internal and external connections: A systematic review. Int. J. Oral Maxillofac. Implants. 2018;33:580–589. doi: 10.11607/jomi.6190. [DOI] [PubMed] [Google Scholar]
- 31.Windael S., Collaert B., de Buyser S., de Bruyn H., Vervaeke S. Early peri-implant bone loss as a predictor for peri-implantitis: A 10-year prospective cohort study. Clin. Implant Dent. Relat. Res. 2021;23:298–308. doi: 10.1111/cid.13000. [DOI] [PubMed] [Google Scholar]
- 32.Spinato S., Stacchi C., Lombardi T., Bernardello F., Messina M., Zaffe D. Biological width establishment around dental implants is influenced by abutment height irrespective of vertical mucosal thickness: A cluster randomized controlled trial. Clin. Oral Implants Res. 2019;30:649–659. doi: 10.1111/clr.13450. [DOI] [PubMed] [Google Scholar]
- 33.Spinato S., Stacchi C., Lombardi T., Bernardello F., Messina M., Dovigo S., Zaffe D. Influence of abutment height and vertical mucosal thickness on early marginal bone loss around implants: A randomised clinical trial with an 18-month post- loading clinical and radiographic evaluation. Int. J. Oral Implantol. 2020;13:279–290. [PubMed] [Google Scholar]
- 34.Van Doorne L., Gholami P., D’haese J., Hommez G., Meijer G., de Bruyn H. Three-dimensional radiographic outcome of free-handed flaplessly placed mini dental implants in edentulous maxillae after 2-years function. J. Clin. Med. 2020;9:2120. doi: 10.3390/jcm9072120. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The associated data of a statistical nature can be requested to: jl.lopez@ub.edu & evelasco@us.es.