Table 7.

Encapsulation efficiencies (EE%) of antitumor compounds 1 and 2. SD is the standard deviation of three independent assays.

System EE% ± SD%
Compound 1 Compound 2
Magnetoliposomes with core-shell NPs 99.3 ± 0.8 99.9 ± 0.5
Magnetoliposomes with decorated NPs 98.5 ± 1.3 99.8 ± 0.6