Skip to main content
. 2021 Nov 24;7(4):230. doi: 10.3390/gels7040230

Table 4.

Composition, experimental vs. predicted value with percentage error of optimized α-MNG-PLGA NPs.

Variables Optimum Composition Response Observed Value of Response Predicted Value of Response Percentage Error
X1 3.39 % w/v Y1 168.06 ± 17.02 150.87 11.39
X2 1.82 % w/v Y2 0.201 ± 0.01 0.214 −6.07
X3 8.79 min Y3 84.26 ± 8.23 79.16 6.44

Predicted error (%) = (observed value − predicted value)/predicted value×100%. X1: Polymer concentration (% w/v); X2, Surfactant concentration (% w/v), X3: Sonication time; Y1: Particle size (nm), Y2: PDI, Y3: Entrapment efficiency (%).