Skip to main content
. 2021 Nov 29;31(1-2):197–205. doi: 10.1007/s11666-021-01284-x

Table 4.

Measured residual stress on the surface and inside of as-sprayed and heat treated cold sprayed samples using X-ray diffractometry

Sample Depth Residual Stress, MPa
Before heat treatment After heat treatment
Longitudinal (0°) 45° Transverse (90°) Longitudinal (0°) 45° Transverse (90°)
Inconel 625 Surface 598 752 974 −56 −45 −36
Inconel 625 1 mm −195 −159 −229 −54 −32 −46
Inconel 718 Surface −160 −65 27 −161 −193 −158
Inconel 718 1 mm −199 −133 −225 35 −20 7