Skip to main content
. 2021 Nov 29;28(1):2510–2524. doi: 10.1080/10717544.2021.2008051

Table 3.

Statistical analysis of the experimental data with ANOVA and the predicted and observed results of the optimized EPL-NCs.

Response F-value Model p value Lack of fit Lack of fit p value R 2 Adjusted R2 Predicted mean value Range for mean values at 95% confidence Obtained value Error (%)
Nanocrystal size (nm) 151.24 <.0001 1.18 .4053 0.9913 0.9847 45.2 42.94–47.46 46.8 ± 0.5 3.5
Dissolution efficiency (%) 112.46 <.0001 0.516 .6254 0.9912 0.9824 95.8 91.01–100.59 96.0 ± 1.5 0.2

The polynomial equations generated after the statistical analysis are as follow:

Nanocrystal size=+5.23A + 5.68B5.97AB0.3330AC0.7776AD1.31BD+3.54ABD.  

Dissolution efficiency=+69.33A + 61.05B+91.33AB+2.43AC+5.39AD +3.01BC+11.12BD +13.20ABC.

p < .05 represents statistically significant difference. For the obtained values, data are presented as mean ± S.D. (n = 3).

Error (%)=(obtained value – predicted value)/predicted value × 100.