Table 4.

Corneal biomechanical properties measured by Corvis ST.

Parameters Stage 1 (n = 42) Stage 2 (n = 26) Stage 3 (n = 12) Unadjusted Adjusted
Diff.a (p) Diff.b (p) Diff.c (p) Diff.d (p)
A1-Length, mm 1.79 ± 0.05 1.84 ± 0.05 1.92 ± 0.09 0.06 (<0.001) 0.13 (<0.001) 0.04 (0.07) 0.10 (<0.001)
A1-Time, ms 6.89 ± 0.25 6.83 ± 0.23 6.66 ± 0.39 −0.07 (0.31) −0.24 (<0.01) −0.08 (0.24) −0.24 (<0.01)
A1-Velocity, m/s 0.14 ± 0.01 0.14 ± 0.02 0.16 ± 0.03 0.00 (0.79) 0.01 (0.07) 0.00 (0.88) 0.01 (0.10)
HC-Time, ms 17.28 ± 0.47 17.39 ± 0.49 17.29 ± 0.31 0.10 (0.37) 0.00 (0.99) 0.10 (0.38) 0.00 (0.99)
Peak distance, mm 2.37 ± 0.15 2.37 ± 0.15 2.47 ± 0.12 −0.01 (0.88) 0.09 (0.06) −0.00 (0.99) 0.09 (0.05)
HC Radius, mm 6.45 ± 0.62 6.46 ± 1.32 6.49 ± 0.76 0.01 (0.96) 0.04 (0.90) −0.01 (0.95) 0.01 (0.98)
DA, mm 1.18 ± 0.12 1.19 ± 0.1 1.2 ± 0.15 0.01 (0.79) 0.02 (0.68) 0.05 (0.23) 0.07 (0.22)
A2-Length, mm 1.64 ± 0.35 1.86 ± 0.31 2.02 ± 0.28 0.21 (0.01) 0.37 (<0.001) 0.06 (0.59) 0.19 (0.19)
A2-Time, ms 21.87 ± 0.37 21.89 ± 0.33 21.89 ± 0.54 0.01 (0.90) 0.01 (0.93) −0.02 (0.87) 0.05 (0.68)
A2-Velocity, m/s −0.41 ± 0.07 −0.38 ± 0.07 −0.38 ± 0.06 0.03 (0.13) 0.03 (0.26) 0.01 (0.74) 0.00 (0.93)

Data shows the mean ± SD. General linear analysis was performed to test differences (Diff.) between three groups. Bivariate analysis:

a

stage 1 vs. stage 2;

b

stage 1 vs. stage 3.

c

Multivariate analysis: stage 1 vs. stage 2;

d

stage 1 vs. stage 3.

A1-length, cord length of applanation 1; A1-time, time from starting until applanation 1; A1-velocity, the speed of applanation 1; HC-time, time from starting until highest concavity; Peak distance, distance of the apexes at highest concavity; HC Radius, central concave curvature at highest concavity; DA, maximum deformity amplitude at the corneal apex; A2-length, cord length of applanation 2; A2-time, time from starting until applanation 2; A2-velocity, the speed of applanation 2.